INSTALLATION
Method 1: Install the duct(s) from the outside of the home down to the location of the exhaust
EN
Method 2: Install the duct(s) from the outside of the home to the ceiling over the exhaust
Use foil HVAC tape (not grey cloth duct tape) to seal all joints. A complete listing of available
Hestan ducting materials is provided on the back page of this instruction sheet.
TRANSITION HEIGHTS:
Dual Blower (WM2L, 600 CFM): none - 8" round duct will connect directly to the top of the
Single and Dual Blower (WM1L + WM2L, 900 CFM): 6" round duct will connect directly to the
Two Dual Blowers (Two WM2Ls, 1200 CFM):
CONNECTION DIAGRAMS
Wall side
12
©2018 Hestan Commercial Corporation
(CONT.)
outlet(s) on the top of the hood allowing room for the transition (if applicable). If a
transition is used, install duct down to the location of the transition outlet plus 1".
This will allow the transition to engage 1" inside of duct.
outlet(s) on the hood. The end of the duct(s) should extend 1" below the ceiling.
hood.
top of the hood; 8" round will connect directly to the top of the hood.
Or use optional multi-blower transition (AKVT6810, sold separately). See "Vent
Accessories" on page 17 for details.
Two 8" round ducts connect directly to the top of the hood.
Or use optional multi-blower transition (AKVT6812, sold separately). See "Vent
Accessories" on page 17 for details.
Connection diagram (30-36" width)
Wall side
1 3/4"
[4.4 cm]
Electrical
Motor
Cooling
Vent
8" [20.3 cm] round
WM2L Dual Blower (600 CFM )
Connection Diagram (42" Width)
5 1/2"
7 5/16"
[14 cm]
[18.6 cm]
Electrical (2)
8" Round
WM2L Dual + WM1L Single Blower (900 CFM)
5 1/2"
[14 cm]
5 1/4"
[13.3 cm]
Centerline
of hood
7 5/16"
[18.6 cm]
Motor
5 1/4"
Cooling
[13.3 cm]
Vent (3)
Centerline
of hood
(Top View)
1 7/8"
[4.8 cm]
1 3/4"
[4.4 cm]
6" [15.2 cm]
round
(Top View)