5 |
Display functions FOX-260
Pos.
D
isplay screens
:
4
4
Battery 1 Type
AGM
GEL
<<
5
5
Contrast
50 %
<<
25
Meaning:
Battery type B 1
ACID
>>
Contrast setting of the
display
>>
5 |
Display functions FOX-260
Significance of the data output:
Battery 1 = Present battery voltage on terminal B1
ICharge
= Present charge current
ISolar
= Present current generated by the modules
(this value may be greater than ICharge when the
charge controller reduces the charge current to prevent
a battery overcharge)
IOut
= Present load current
Significance of the parameter displays:
Mode Output:
Sets the type of use of the output terminal. 4 functions are available:
!
AUTO
!
LAMP
!
ON
!
OFF
When
AUTO
is selected, the controller automatically witches off the
consumers if the battery is discharged too much. If the battery voltage
increases again, the consumers will be switched on again
automatically.
When
LAMP
is selected, the controller presumes that a small light (e.g.
as orientation light) is connected to the output terminal. This light will
then be switched on every night, as soon as the module does no
longer supply charge current, and switched off again at dawn. The
total discharge protection remains active.
When
ON
or
OFF
is selected, the status of the terminal remains
permanently in the selected position. In the case of
battery 1 is applied to the terminal.
ON
the voltage of
26