AFF16 or AFFseries-2, 2
ways of wiring :
*
Wiring 1, AFF is connected to
D connector of SNA.
*
Wiring 2, AFF is connected to
RJ45 connector of SNA.
Wiring 2
AFF16 or AFFseries
AFF 16
dB
(C)
(A)
OFFSET ON
RJV 30
*
6 x 0,22² wire
RMC 55
WIRING.
1°)
To access connectors remove the hood from the rear panel
2°)
Connect SNA 50-2 to mains (230V 50Hz) using socket
3°)
Connect RJV 30 to socket L, using a 6 leads wire.
Made in France
RJV 30
Loops + RJV 40
230V
50/60Hz
14W
T 250 mA L
Window contact : type ILS
(contact switched on = closed door)
RJV 30
Socket
Female
Plug
Female
Plug
6 5 4 3
1
6 5 4 3
2
POWER
RJV 30
LOOPS + RJV 40
ON
OFF
RJV 30
6 x 0,22² wire
4°)
Connect the sensor CAP60 to the XLR E and F using two shielded balanced wires or one wire of 2 pair.
Note
:
Thanks to the internal balanced output amplifier CAP60 allows use of long wires, without interference often found in
such a lay out.
Made in France
RJV 30
230V
50/60Hz
14W
T 250 mA L
RJV 30
Socket
Screw
Female
Plug
6 5 4 3
2
1
POWER
RJV 30
ON
OFF
CAP 60
AMIX
SNA70 RACK WIRING
Wiring 1
AFF16 or AFFseries
AFF 16
dB
(C)
(A)
OFFSET ON
Supply
power
2 Shielded pair wire
Left/Righ
INPUT
OUTPUT
CAP 60 connector
AFF Series connector
Analog direct OUT
Male
1
2
XLR Plug
ILS
3
1
2
2
1
CAP 60
-
AFF Plug
Socket
1
2
3
4
5
6
1
2
3
4
5
6
-
3
-
3
-
3
Male XLR Plug
Female XLR Plug
2
1
1
2
3
Female
Female
XLR Plug
XLR plug
1
2
INPUT
OUTPUT
CAP 60
AFF
SERIES
PUSH
PUSH
PUSH
AFF SERIES
WITH SUPPLY
R
L
R
L
OUT
IN
ANALOG
TO AFF
DIRECT
OUT
Loops + RJV 40
INPUT
OUTPUT
CAP 60 connector
Window contact : type ILS
(contact switched on = closed door)
1
2
Male
XLR Plug
3
ILS
CAP 60
1
2
2
1
Socket
1
2
3
4
5
-
-
3
3
Female
3
-
Plug
Male XLR Plug
Female XLR Plug
1
2
Female
XLR plug
6 5 4 3
2
1
INPUT
OUTPUT
CAP 60
PUSH
PUSH
LOOPS + RJV 40
R
L
R
L
OUT
2 balanced shielded
pair wire
Power
3 x 1,5² wire
supply
SNA 70
2 Shielded pair wire
2 Shielded pair wire
Left/Righ
O.
All connectors internal view
VCA
1
5
9
Sub-D 9 F
EIA / TIA
V+
plug
568 B or A
12V DC
-
wiring to AFF
300 mA
DC Balanced
VCA
POWER
TO VCA
SUPPLY
FOR AFF
AFF Series connector
All connectors internal view
Analog direct OUT
VCA
-
AFF Plug
5
1
9
6
1
2
3
4
5
6
Sub-D 9 F
EIA / TIA
V+
plug
Screw
Screw
568 B or A
12V DC
-
wiring to AFF
300 mA
DC Balanced
2
1
3
Female
XLR Plug
AFF
SERIES
PUSH
AFF SERIES
VCA
WITH SUPPLY
IN
ANALOG
TO AFF
POWER
TO VCA
DIRECT
SUPPLY
OUT
FOR AFF
16
Safety power supply
PC
CAP 60
L
RJV30
socket
RJV30 from soldering side
Wiring
Male 3 pts XLR plug
3
to connect to F
1
2
1
3
2
1
CAP60 Plug
PAM 15
Wiring
1
2
Male 3 pts XLR plug
3
to connect to E
3
2
SNA 70