Front Panel Description - AMIX SNA 70 Manuel Utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1 -
Channel measurement test light indicator.
2 -
Sensor corded connection default light indicator.
3 -
Audio presence light indicator.
4 -
Key associated to a light indicator. Allows to choose the analysis curve, used for historic.
 Pressed, light on: weighted curve analysis (Choose weighting by 5).
Released, light off: linear analysis
5 -
Key associated to a light indicator. Allows to choose the weighting, used for historic.
Pressed, light on: enable weighted filter A .
 Released , light off: enable intermediate filter M.
6 -
Key associated to a light indicator. Allows to set the reference for regulation.
 Pressed, green light on: SNA70 refers to the stereo line input.
 Released , red light on: SNA70 refers to the acoustic sensor.
7 -
Key associated to a light indicator. Allows to choose the analysis curve used for regulation of broadband.
 Pressed, light on: weighted analysis (Choose weighting by 8)
 Released, light off: linear analysis or filter card.
8 -
Key associated to a light indicator. Allows to choose the weighting used for regulation of broadband.
 Pressed, light on: enable A weighting filter.
 Released , light off: enabled intermediate filter M.
9 -
Audio presence on left and right inputs of SNA70. Allows to check quickly if a audio source is connected correctly to SNA70
input.
10 -
Scale allowing to control sound reduction level of SNA70. Attention this scale shows only the audio reduction in broadband
and not the reduction by octave band.
11 -
Control section of reduction by octave band. For this, there is no choice for the weighting, specifically it is the weighting Z
(included), ie linear in frequency.
 Pressed, green light on : SNA70 refers to the stereo line input for regulation by octave.
 Released , red light on: SNA70 refers to the the acoustic sensor for regulation by octave.
12 - The frequencies LEDS 63Hz, 125Hz, 250Hz, 500Hz, 1KHz, 2 KHz, 4 KHz light as soon as the acoustic pressure level
programmed for this band is reached and the regulation goes into service.
13 -
Keyboard used to modify parameters.
14 -
LCD display.
15 -
Top cover (plexiglas) opening detector.
16 -
Power on indicator.
17 -
Set of three indicators showing acoustic pressure variation in broadband.
Fixed Green Computed short Leq 1s is 3dB below instruction threshold.
Fixed Yellow

Fixed Red
The supplied RJV30 provided with SNA 50-2, remotely displays this information. It should be placed
In summary :
R
J
V
The maximun user allowance in broadband , instruction threshold is Leq 1 seconde.
AMIX

FRONT PANEL DESCRIPTION

.
:
Computed short Leq 1s Instruction threshold
:
Computed short Leq 1s is +/-3dB around instruction threshold
Instruction threshold
:
Computed short Leq 1s is 3dB over instruction threshold.
Computed short Leq 1s
Computed short Leq 1s
Instruction threshold
Computed short Leq 1s Instruction threshold
<
- 3 dB
Computed short Leq 1s
<
Instruction threshold
>
Instruction threshold + 3dB
>
- 3 dB
Computed short Leq 1s
<
<
7
- 3 dB
Instruction threshold
<
+ 3dB
Instruction threshold
<
- 3 dB
+ 3dB
+ 3dB
SNA 70

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Sna 70 bSna 70 r

Table des Matières