1 -
Channel measurement test light indicator.
2 -
Sensor corded connection default light indicator.
3 -
Audio presence light indicator.
4 -
Key associated to a light indicator. Allows to choose the analysis curve, used for historic.
Pressed, light on: weighted curve analysis (Choose weighting by 5).
Released, light off: linear analysis
5 -
Key associated to a light indicator. Allows to choose the weighting, used for historic.
Pressed, light on: enable weighted filter A .
Released , light off: enable intermediate filter M.
6 -
Key associated to a light indicator. Allows to set the reference for regulation.
Pressed, green light on: SNA70 refers to the stereo line input.
Released , red light on: SNA70 refers to the acoustic sensor.
7 -
Key associated to a light indicator. Allows to choose the analysis curve used for regulation of broadband.
Pressed, light on: weighted analysis (Choose weighting by 8)
Released, light off: linear analysis or filter card.
8 -
Key associated to a light indicator. Allows to choose the weighting used for regulation of broadband.
Pressed, light on: enable A weighting filter.
Released , light off: enabled intermediate filter M.
9 -
Audio presence on left and right inputs of SNA70. Allows to check quickly if a audio source is connected correctly to SNA70
input.
10 -
Scale allowing to control sound reduction level of SNA70. Attention this scale shows only the audio reduction in broadband
and not the reduction by octave band.
11 -
Control section of reduction by octave band. For this, there is no choice for the weighting, specifically it is the weighting Z
(included), ie linear in frequency.
Pressed, green light on : SNA70 refers to the stereo line input for regulation by octave.
Released , red light on: SNA70 refers to the the acoustic sensor for regulation by octave.
12 - The frequencies LEDS 63Hz, 125Hz, 250Hz, 500Hz, 1KHz, 2 KHz, 4 KHz light as soon as the acoustic pressure level
programmed for this band is reached and the regulation goes into service.
13 -
Keyboard used to modify parameters.
14 -
LCD display.
15 -
Top cover (plexiglas) opening detector.
16 -
Power on indicator.
17 -
Set of three indicators showing acoustic pressure variation in broadband.
Fixed Green Computed short Leq 1s is 3dB below instruction threshold.
Fixed Yellow
Fixed Red
The supplied RJV30 provided with SNA 50-2, remotely displays this information. It should be placed
In summary :
R
J
V
The maximun user allowance in broadband , instruction threshold is Leq 1 seconde.
AMIX
FRONT PANEL DESCRIPTION
.
:
Computed short Leq 1s Instruction threshold
:
Computed short Leq 1s is +/-3dB around instruction threshold
Instruction threshold
:
Computed short Leq 1s is 3dB over instruction threshold.
Computed short Leq 1s
Computed short Leq 1s
Instruction threshold
Computed short Leq 1s Instruction threshold
<
- 3 dB
Computed short Leq 1s
<
Instruction threshold
>
Instruction threshold + 3dB
>
- 3 dB
Computed short Leq 1s
<
<
7
- 3 dB
Instruction threshold
<
+ 3dB
Instruction threshold
<
- 3 dB
+ 3dB
+ 3dB
SNA 70