Available Flows; Warnings; Standards Of Reference - aqua HC150 Serie Manuel De Service Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

HC150 / HC101
Analog solenoid driven dosing pump

1.2 Available flows

For each series it is possible to have several models depending on the performance you wish to obtain:
Description
HC150 Mod. 1
HC150 Mod. 2
HC150 Mod. 3
Description
HC101 Mod. 1
HC101 Mod. 2
HC101 Mod. 3
HC101 Mod. 4
HC101 Mod. 5

1.3 Warnings

The manual for the HC150 / HC101 series pumps has the purpose of providing all of the information required for
the correct installation and maintenance of the products that allows you to achieve the best results over time.
To this end it is extremely important that you read the warnings listed below as they provide the necessary
indications for safe installation, operation and maintenance.
 At the time of receiving the product check the integrity of the pump and all of its parts. In
case of irregularities promptly notify qualified personnel before performing any
operations.
 This manual must be stored carefully for future consultation.
 Before installing the pump make sure that the details provided on the adhesive plate
attached to the pump correspond to those of the electrical system.
 Do not handle the equipment with wet hands or feet.
 Do not leave the equipment exposed to atmospheric agents.
 The equipment must be handled by qualified personnel.
 If any irregularities are experienced during pump operation, cut off the power supply and
contact one of our customer care centres repairs.
 In order for the pump to operate correctly it is necessary to use original parts or
accessories. The manufacturer is relieved of any responsibility in the case of any
breakdowns due to tampering or use of non-conforming parts and accessories
 The electrical system must be in compliance with the regulations in force of the country
where it is built.
 The ambient temperature for operation must not exceed 45° C.

1.4 Standards of reference

Our pumps are manufactured according to General Standards in force and in compliance with the following
European Directives:
n° 2004/108/CE " e s.m.i.
n° 2006/95/CE "DBT Low Voltage Directive" e s.m.i.
n° 2011/65/UE , 2012/19/UE "direttive RoHs e WEEE" e s.m.i.
ADSP9500090
Flow
Pressure
L/h
Bar
1,5
5
3
7
5
8
Flow
Pressure
L/h
Bar
2
8
5
5
7
2
7
4
8
2
10
0
3
12
4
10
5
8
10
4
12
2
14
0
2
20
2,5
18
3
15
Rev.2.5 09.09.2015
Frequency (max)
BPM
120
120
150
Frequency (max)
BPM
120
150
150
180
75
INTRODUCTION
ENGLISH
Flow
cc per dose
0,21
0,42
0,56
Flow
cc per dose
0,28
0,69
0,97
0,78
0,89
1,11
0,33
0,44
0,55
0,93
1,11
1,30
0,44
0,56
0,67
23

Publicité

Table des Matières
loading

Table des Matières