This range hood is equipped standard with a single blower vertical duct option. To convert from single blower
vertical ducting to dual blower vertical ducting please following the instructions below.
1. Disconnect blower plug and white and black
power cables.
3. Remove (4) screws attaching single blower to
single blower plate.
5. Position dual blower inside hood body as
shown. Be sure to tuck dual blower plate into
blower plate tabs. Secure dual blower by (4)
screws previously removed from step 2.
2. Remove (4) screws from interior of hood body
attaching single blower plate to top of hood
body. Remove single blower and single blower
plate.
4. Attach single blower to dual blower plate by (4)
previously removed screws from step 3.
6. Attach 10" round blower collar to top of hood
body by (4) M4 x 8 screws. Connect blower
wire extension cable to new blower and connect
plugs from each blower to female plugs behind
10
switch panel.
www.zephyronline.com