Trotec IDS 30 D Manuel D'utilisation page 17

Masquer les pouces Voir aussi pour IDS 30 D:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 20
Problem
Operation indi-
cator
Fan does not start run-
switched off
ning and flame is not
ignited
Fan does not start run-
flashing orange
ning or switches off dur-
light
ing start-up or operation
Fan switches off during
continuous red
start-up or operation
light
EN
Reset button
Cause
Self-diagnostic
indicator
-
Control device is incor-
rectly set
Control device defective
-
no power supply
Voltage < 175 V
Voltage > 265 V
flashing orange
Flame is present prior
light
to the ignition of the
transformer
Photoelectric cell defective - Have the photoelectric cell replaced by the cus-
flashing red light
Motor winding interrupted
or flashing red/
or blown
green light
Motor bearing blocked
Motor capacitor blown
no ignition
Flame
defective
Photoelectric cell defective - Have the photoelectric cell cleaned or replaced by
Burner is not or only in-
sufficiently supplied with
heating oil
Operating manual – IDS 30 D
Error correction
- Check if the control equipment is correctly set
(e.g. the temperature set at the thermostat must
be higher than the room temperature).
- Have the control device replaced by the customer
service.
- Check the characteristics of the electrical system
(230 V -1~ - 50 Hz).
- Check the function and position of the selector
switch.
- Check if the fuse is intact.
- Check the supply voltage. The device will auto-
matically restart if the voltage exceeds 190 V.
- Check the supply voltage. The device will auto-
matically restart if the voltage falls below 250 V.
- Contact the customer service and have the device
cleaned and heating oil residues removed from
the combustion chamber.
tomer service.
- Have the motor replaced by the customer service.
- Have the motor bearing replaced by the customer
service.
- Have the motor capacitor replaced by the cus-
tomer service.
- Check the connections of the ignition cables to the
electrodes and the transformer.
- Check the position and the distance of the
electrodes.
- Check if the electrodes are clean.
- Have the transformer replaced by the customer
service.
control
system
- Have the flame control equipment replaced by the
customer service.
the customer service.
Contact the customer service in order to:
- have the integrity of the coupling between the
pump and motor checked.
- have the heating oil circuit checked for air that
may have entered the circuit and to have the tight-
ness of the lines and filter seal checked.
- have the nozzle cleaned or replaced.
B-7

Publicité

Table des Matières
loading

Table des Matières