4. General safety instructions
Please observe the following safety instructions!
Any non-compliance with these instructions may
have serious consequences for the health of per-
sons and could result in property damage and
damage to the environment.
Risk of explosion!
•
Do not operate the device in potentially flammable or explosive
environments. Do not install it in such environments, either.
•
Do not place the device on a flammable surface.
•
Remove any inflammable materials and chemicals from the im-
mediate operating environment.
Functional impairment of and damage to the device!
•
Do not use the device outdoors.
•
Install the device in a stable position.
•
Keep the intake and exhaust openings free.
•
Do not cover the device during operation.
•
Only disconnect the device from the mains once it has cooled
down completely.
•
Do not use any chemicals for cleaning the device.
Risk of injury and damage to property due to defective devices!
•
Before each use of the device, check its accessories and connec-
tion parts for possible damages. Do not use any defective devices
or device parts.
•
Do not use the device if you detect any damage to its plug and
cables. Defective power cables represent a serious health threat.
Danger to life through electrical shock!
•
Only connect the device to power sources that are in good tech-
nical order. Do not use damaged wall outlets!
•
Pull the connection cable out of the wall outlet by pulling it at
its plug.
•
Do not touch electrical connection cables when your hands are
wet!
•
Protect the electrical connection cables against damage caused
by, for example, animals.
•
Do not carry out any changes or repairs on the device!
•
Do not expose the device to any liquids.
•
Do not apply any liquids to the interior of the device. If this does
happen nevertheless, pull out the power cord and have the de-
vice checked by a specialist workshop.
Risk of injury!
•
Do not insert any objects into the intake and exhaust opening of
the device.
•
Do not reach into the existing openings.
•
Do not leave children or animals unattended near the operating
device!
•
Do not operate the device in rooms with insufficient supply of
combustion air.
B-2
•
Risk of burns! Persons present in the installation area must ob-
serve a minimum distance of 2 metres to the heating unit! Warn-
ing signs must alert of the source of danger.
Risk of environmental pollution!
•
Do not let any leaked fuel seep away into the soil and prevent it
from entering the sewer system.
5. Function and product characteristics
The oil heating unit IDS 30 D is used to heat up room air in order to
achieve a fast heating of well ventilated rooms.
The oil heating unit is operated with heating oil. The device features an
indirect combustion. This means that the warm air and the combustion
gases are released into the surrounding area.
A selection of two operating modes ensures that the oil heating unit can
be controlled both manually by the user as well as automatically with the
support of the thermostat.
6. Technical data
Parameter
Article number
Electrical connection
Frequency
Nominal current max.
Power consumption
Air volume
Fan
Nominal heat load max.
Nominal heat output
Temperature increase ΔT
Oil consumption max.
Tank capacity
Air transportation hose connection
Chimney connection
Thermostat connection
Combustion
Nozzle
Pump pressure
Sound pressure level (at distance
of 1 m)
Length
Width
Height
Weight
indicates the temperature increase. ΔT + ambient temperature = exhaust air
1)
temperature
optional
2)
Operating manual – IDS 30 D
Type IDS 30 D
Value
1.430.000.025
230 V
50 Hz
1.25 A
272 W
605 m³/h
Axial fan
38.4 kW
-
-
1)
3.66 l/h
42 l
-
2)
-
series
direct
0.60-80° S (gal/h)
13.5 bar
69 dB (A)
1075 mm
440 mm
615 mm
25 kg
EN