NOTE:
Instructions for continuous use of the FR-PU07 (parameter unit)
For the FR-A800 series, many functions (parameters) have been added. When setting these parameters, the
parameter names and setting ranges are not displayed.
Only the parameter with the numbers up to "999" can be read and set. The parameters with the numbers high-
er than "999" cannot be read or set.
Many protective funcions have been added for the FR-A800 series. These functions are available, but all faults
are displayed as "Fault". When the faluts history is checked, "ERR" appears. Added faults will not appear on
the parameter unit. (However, MT1 to MT3 are displayed as MT.)
Parameter copy/verification function are not available.
Copying parameter settings
The FR-A700 series' parameter setiings can be easily copied to the FR-A800 series by using the setup soft-
ware (FR Configurator2). (Not supported by the setup software FR-SW3-SETUP or older.)
Comparison of FR-A700 and FR-A800
Item
Control method
Added functions
Brake transistor (brake resistor usable)
Maximum
V/F control
output fre-
Advanced magnetic flux
quency
vector control
Real sensorless vector
control
Vector control
PM sensorless vector con-
trol
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
FR-A700
V/F control
Advanced magnetic flux vector control
Real sensorless vector control
Vector control (with plug-in option)
PM sensorless vector control (IPM mo-
tor)
---
Built in for the FR-A720-0.4K to 22K
Built in for the FR-A740-0.4K to 22K
400 Hz
120 Hz
120 Hz
120 Hz
300 Hz
4
FR-A800
V/F control
Advanced magnetic flux vector control
Real sensorless vector control
Vector control (with plug-in option)
PM sensorless vector control (IPM mo-
tor/SPM motor)
USB host function
Safety stop function
etc.
Built in for the FR-A820-00046(0.4K) to
01250(22K)
Built in for the FR-A840-00023(0.4K) to
03160(55K)
590 Hz
400 Hz
400 Hz
400 Hz
400 Hz
Table continues...