Télécharger Imprimer la page

Alliance Laundry Systems FR-A800 Serie Instructions page 10

Publicité

Les langues disponibles

Les langues disponibles

www.groupdynamics-laundry.com
sales@groupdynamics.lv
6. Secure all wires and cover frequency inverter drive.
Use original assembling parts.
7. Load correct frequency inverter drive parameters and check
correct drive function.
Monitor motor current during constant speed and during ac-
celeration or deceleration, torque (stable drum acceleration) –
see parameter 9 in official parameter list (can be obtained
from Alliance Laundry Systems; for skilled technicians only).
Verify the switching of second and third acceleration / decel-
eration ramp is correct – the frequency must raise/drop by
1÷2 Hz/s max., see the Service Info screen on the control
board display. If the frequency changes by more than 5 Hz/s,
check the wire bridges on inverter terminals and correct posi-
tion of switch SINK – SOURCE, see the schematics above.
In case you have further technical questions, do not hesitate to
take contact your distributor.
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
10
Form No. 12-15-425ENR1

Publicité

loading