For rectangular ducted discharge installations only
1
Remove wrap from transition.
2
Attach rectangular transition over knockout opening with
3 - 3.5 x 6.5 mm screws.
3
Make sure damper pivot is nearest to top/back edge of
hood.
Pivot
For round ducted discharge installations
Install 7" (17.8 cm) transition with the screws available on
the kit (purchase separately, see Optional accessories and
consumable parts section).
NOTE: The round transition can be installed up to 1 inch on
either side of the hood center to accommodate off-center
ductwork. In extreme offcenter installations, one end of the
duct connector may need to be trimmed to clear the electrical
cable clamp.
7" round transition
Mark and Cut Vent Opening
Use the hood as a template and mark the locations on the
cabinet for the keyhole screw slots.
Select the vent option that your installation will require and
proceed to that section
For a non-vented (recirculating) installation
No additional steps needed.
Top/back edge
Rectangular transition
Outside top exhaust
(Vertical duct– 3
1
"x 10" rectangular transition)
4
1
Use the diagram or the hood as a template and mark the
locations on the cabinet for ductwork and electrical wiring
and keyhole screw slots.
Hood mounting screws (4)
13
" (30" hood)
15
1 6
16
" (36" Hood)
15
1 6
Cabinet front
Cabinet bottom
5
Vertical duct
5"
access hole
1
"
1
4
Wood shims (recessed
Centerline
bottom cabinets only)
1
Use saber or keyhole saw to cut a rectangular opening for
vent.
Outside top exhaust
(Vertical duct–7" round transition)
1
Use the diagram or the hood as a template and mark the
locations on the cabinet for ductwork, electrical wiring
and keyhole screw slots.
Hood mounting screws (4)
13
" (30" hood)
15
16
16
" (36" Hood)
15
16
Cabinet front
Cabinet bottom
Access hole for
7" round duct
5"
Wood shims (recessed
Centerline
bottom cabinets only)
2
Use saber or keyhole saw to cut a round opening for vent.
Outside rear exhaust
(Horizontal duct– 3
"x 10" rectangular transition)
1
4
1
Use the diagram or the hood as a template and mark the
locations on the cabinet for ductwork, electrical wiring
and keyhole screw slots.
Cabinet front
3
"
Horizontal duct
3
4
access hole
Cabinet
5
"5
1
bottom
4
13
" (30" hood)
15
16
16
" (36" Hood)
15
16
Hood mounting
Centerline
screws (4)
3
Use saber or keyhole saw to cut a rectangular opening for
vent.
13
" (30" hood)
15
1 6
16
" (36" Hood)
15
1 6
12
"
1
2
"
5
"
1
1
4
4
1
"
1
4
1
Electrical access
hole (in cabinet
bottom)
13
" (30" hood)
15
16
16
" (36" Hood)
15
16
12
"
1
2
HOLE
1
"
1
4
7" DIA.
1
Electrical access hole
(in cabinet bottom)
"
1
"
1
9
8
16
"
1
4
12
"
7
16
13
" (30" hood)
15
16
16
" (36" Hood)
15
16
Electrical access hole
(in wall)
10
"
1
2
"
1
2
10
"
1
2
"
1
2
7