Operating Instructions & Parts Manual
Needle/Nozzle
Replacement (if needed)
Note: NEEDLE MUST BE REMOVED
BEFORE NOZZLE.
1. Unscrew
material
control
knob at
rear of
gun.
2. Pull trig-
ger to
push nee-
dle back.
3. Fit wrench
around nee-
dle sleeve
and push
out handle
toward
opening.
4. Use wrench to pull needle out.
5. Unscrew
retaining
ring.
www.chpower.com
Retaining
Ring
6. Remove air
cap.
7. Use wrench
to remove
nozzle.
8. Screw new
nozzle on.
9. Replace air
cap and
screw
retaining
ring back
on.
10. Insert needle to be used, and fit
securely into hole.
11. Replace
material
control
knob.
4
Air Cap
Retaining
Ring
Nozzle