GATE FITTING
The gate fitting must be installed so that it is horizontal
relative to the post bracket. The distance between the gate
bracket and post bracket is referred to as the "arm span".
When the gate is closed, the drive mechanism is 99%
extended. When the gate is opened, the drive mechanism is
1% extended. Fully retracting or extending the
plunger/spindle in operation (with gate) damages the drive
mechanism and voids the warranty. It is absolutely imperative
to comply with the required arm span under all
circumstances!
For steel gates, fixings should be welded on or through
bolted. When through bolting the gate, use large washers or
a plate on the other side. The drive mechanism exerts an
extremely high force on this joint.
Fixings must be through bolted for wooden gates. It is
recommended that metal plates be fitted on either side of the
gate, to prevent the fixings from becoming loose.
RELEASE
The drive mechanism can be released. The gate can then be
opened and operated manually (power failure). With a new
drive mechanism, the release action may sometimes feel
stiff/jerky. This is normal and has no effect on function.
Release and Engage
Place the hexagonal key into the hole provided in the cover.
Engage or disengage the motor.
INSTALLING THE DRIVE ARMS
Release the drive. Push the released drive onto the
fittings and secure it by using the supplied bolts and
rings.
If the centre or inner hole, on the hinge plate, is used to fix
the post fixing bracket you MUST cut away the remaining
section of the hinge plate before activating the arms. Failure
to do so will result in breaking the fixing bracket.
Do not use a hammer when you mount the operator on the
bracket.
WIRING
The 3-pole connecting cable is approx. 80 cm long and is laid
in a curve to the controller or a watertight distribution box
located above ground. An approved cable is permanently
installed from the distribution box onwards. The capacitor can
be connected inside the distribution box or in the controller.
MAINTENANCE WORK
The drive mechanism is maintenance free. Check that the gate
fittings and the drive mechanism are securely fixed at regular
intervals (monthly). Release the drive and check that the gate
functions properly. Unless the gate runs smoothly it will not
operate correctly with the drive mechanism. The drive cannot
eliminate the problems caused by a gate that does not work
satisfactorily.
TECHNICAL DATA
Mains supply (Motor)
Current consumption
Power consumption
Capacitor
Max. gate width
Max. gate weight
Protection Class
Connecting cable
Rated Thrust
Travel Speed
Rated operating time
Temperature
Mains supply (Control)
Absorbed power
Protection Class (Box)
D e c l a r a t i o n o f C o n f o r m i t y
Automatic Gate Opener Models ECO300K/KS, ECO400K/KS Series
are in conformity to the applicable
sections of StandardsEN300220-3 • EN55014 • EN61000-3 • EN60555, EN60335-1 • ETS
300 683 • EN60335-1: 2002 • EN60335-2-103: 2003 • EN55014-1: 2000 + A1 + A2 •
EN55014-2: 2001 • EN61000-3-2: 2000 • EN61000-3-3: 1995 + A1 • EN 301 489-3,
V1.3.1 • EN 300 220-3 V1.1.1 • EN13241-1
per the provisions & all amendments
of the EU Directives .........................................2006/95/EEC, 2004/108/EEC, 1999/5/EG
D e c l a r a t i o n o f I n c o r p o r a t i o n
Automatic Gate Opener Models when installed and maintained according to all the
Manufacturer's instructions in combination with a Gate, which has also been installed and
maintained according to all the Manufacturer's instructions, meets the provisions of EU
Directive 89/392/EEC and all amendments.
I, the undersigned, hereby declare that the equipment
specified above and any accessory listed in the manual
B.P.Kelkhoff
Manager, Regulatory Affairs
Chamberlain GmbH
D-66793 Saarwellingen
Januar, 2009
220 – 240Volt ˜ / 50Hz
1,3A
~220W
5μF
2,5m ECO300K/KS
3,5m ECO400K/KS
200kg
I - IP 44
80cm
~250N
approx.20mm/s ECO300K/KS
approx.12mm/s ECO400K/KS
4 minutes
-20
o
C to + 55
o
C
230V/50-60Hz
4 Watt
IP44
conforms to the above Directives and Standard
s.