Installation and maintenance manual
5.1.1.1
List of equipment parameters
Parameter description
Password (shadow)
H2O Set HOT economy cycle
H2O Set HOT automatic cycle
H2O Set COLD
H2O Set for heat pump stop
H2O Set for the enabling of photovoltaic
supplement
H2O Set ANTI-FREEZE
Set point GREEN cycle
Set cold evaporator
Set damaged evaporator
Upper probe calibration
Lower probe calibration
Evaporator probe calibration
Probe type
Decimal point
Unit of measurement
Function associated with the evaporator
probe
Local display data
Remote display data
Display data refresh time specified in
tenths of a second
Work set hysteresis
Minimum auto cycle set point
Maximum auto cycle set point
Minimum economy cycle set point
Maximum economy cycle set point
Work set change block
Code
U.M.
Min
PA
SP1
°C/°F
r3
SP2
°C/°F
r1
SP3
°C/°F
10.0
SP5
°C/°F
r1
SP6
°C/°F
40.0
SP7
°C/°F
0
SP8
°C/°F
0
SP9
°C/°F
-25.0
SP10
°C/°F
-50.0
CA1
°C/°F
-25.0
CA2
°C/°F
-25.0
CA3
°C/°F
-25.0
P0
----
0
P1
----
0
P2
----
0
P4
----
0
P5
----
0
P6
----
0
1/10
P8
0
sec
r0
°C/°F
0.1
r1
°C/°F
10.0
r2
°C/°F
r1
r3
°C/°F
10.0
r4
°C/°F
r3
r5
----
0
Max
Default
Notes
Function reserved for
0
specialised technical staff
r4
55.0
r2
55.0
r2
45.0
SP2
62.0
(56°C for L versions)
100.0
75.0
40
10
100.0
40
25.0
-7.0
25.0
-25.0
25.0
0.0
25.0
0.0
25.0
0.0
0 = PTC
1
1
1 = NTC
2 = PT1000
1 = Decimal point per
1
1
Dy(dysprosium)
temperature
0 = °C
1
0
1 = °F
0 = Disabled
2
2
1 = Defrosting start-stop
2 = Defrosting start
0 = Upper probe
1 = Operative set point
3
0
2 = Lower probe
3 = Evaporator probe
0 = Upper probe
1 = Operative set point
3
0
2 = Lower probe
3 = Evaporator probe
250
5
30.0
7.0
r2
40.0
100.0
70.0
r4
40.0
100.0
62.0
(56°C for L versions)
1 = It is not possible to
1
0
change the set point; it
pag. 18 / 23