• Drain the water out of the cleaner by running it for a few seconds with the cleaner gun lever (22) pressed.
• Turn the master switch (1) to "0" .
• Take the plug out of the power socket.
• Eliminate any remaining pressure in the high pressure hose (35) by keeping the cleaner gun lever (22)
pressed down for a few seconds.
• Wait for the cleaner to cool down.
• Wind up the high pressure hose (35) with due care, making sure it is not bent. For products without a
hose reel, hang it up on its support (10).
• Wind up the power cord (6) and hang it up on its support (10).
• Store the high pressure cleaner in a clean, dry place. Make sure the power cord and the high pressure
hose are not damaged.
Follow the instructions for
MAINTENANCE
SCHEDULE
Every time the cleaner
is used
Once a Week
32
STORAGE
ROUTINE MAINTENANCE
and those provided in the table below.
"STOPPING WORK"
• Check the power cord, the high pressure hose, the connectors, the cleaner
gun and the lance pipe.
Should any of these look damaged, do not use the cleaner for any reason
and contact a
QUALIFIED TECHNICIAN
• Check the water inlet filter (18) and clean it if necessary.
Use a coin (Fig. 1 and 2) to turn the screw (37) anticlockwise and lower the
door (33).
Unscrew the cup (62) and take the filter cartridge (61) out.
Running water or compressed air is generally all that is needed to clean
the filter cartridge. In difficult cases, use a lime scale remover or replace the
filter cartridge. For tough cases, use a lime scale remover or replace it by
contacting a
QUALIFIED TECHNICIAN
Replace the filter and put the cover back, following the above steps in reverse
order.