Normal Usage; Maintenance; Filter Replacement; Ir Lamp Replacement - Trisk CureSaver 2 Manuel D'assemblage, D'utilisation Et Pièces De Rechange

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 9
6.

Normal usage

To prepare the unit for operation:
Set the timers to the recommended times. Timer duration
is set by rotating the timer knobs clockwise until the
desired times are reached. The unit starts immediately
when a timer knob is rotated.
NOTE: The FLASH OFF timer controls the duration of the
half power output of the emitters. The FULL BAKE timer
controls the duration of the full power output of the
emitters. If both FLASH OFF and FULL BAKE timers are
used, the FLASH OFF timer will run down first and upon
switching off will engage the FULL BAKE timer automati-
cally. To stop the unit before the time is up, rotate the
timer(s) counter clockwise to 0
WARNING !
Intensive heat radiation.
Hands, face and other parts of the body
should be exposed as little as possible to
the heat radiation.
FLASH OFF LAMP
FLASH OFF TIMER
FULL BAKE LAMP
FULL BAKE TIMER
FLASH OFF LAMP:
half power.
FLASH OFF TIMER:
FULL BAKE LAMP:
full power.
FULL BAKE TIMER:
6
MAIN SWITCH
illuminates when the
machine is running at
controls the duration of
half power. 0 - 30 min.
illuminates when the
machine is running at
controls the duration of
full power setting.
7.

Maintenance

7.1 Filter replacement

1. Loosen the metal clips at the
cassette side plates.
2. Remove the used filter.
3. Insert the new filter so that the Trisk logo is
visible from the outside.
4. Push the long edges of the
filter into the cassette grooves.
5. Reattach the metal clips.
Attention!
The filter is a consumable and should not be cleaned as
this will result in the loss of its filtering capacity.

7.2 IR lamp replacement

Attention!
Do not touch the aluminium-coated reflector or the new
IR lamp with your fingers. Remove the protective paper
on the IR lamp after you have installed it.
1. Disconnect power supply.
2. Loosen the 2 top screws on
the front plate in accordance
with Section 5.8 of the
assembly instructions.
3. Disconnect the cable connector.
4. Loosen the 4 screws on the ends
of the reflector and remove the
reflector from the plate.
5. Remove the mesh and unscrew
the lamp from the end.
6. Install new lamps in reverse order.
CureSaver 2
Metal clips
420825 rev 2

Publicité

Table des Matières
loading

Table des Matières