6.
Normal usage
To prepare the unit for operation:
Set the timers to the recommended times. Timer du-
ration is set by rotating the timer knobs clockwise
until the desired times are reached. The unit starts
immediately when a timer knob is rotated.
NOTE: The FLASH OFF timer controls the dura-
tion of the half power output of the emitters. The
FULL BAKE timer controls the duration of the full
power output of the emitters. If both FLASH OFF
and FULL BAKE timers are used, the FLASH OFF
timer will run down first and upon switching off it
will engage the FULL BAKE timer automatically.
To stop the unit before the time is up, rotate the
timer(s) counter clockwise to 0
WARNING !
Intensive heat radiation.
Hands, face and other parts
of the body should be ex-
posed as little as possible
to the heat radiation.
FLASH OFF LAMP
FLASH OFF TIMER
FULL BAKE LAMP
FULL BAKE TIMER
FLASH OFF LAMP:
FLASH OFF TIMER:
FULL BAKE LAMP:
FULL BAKE TIMER:
6
▲
illuminates when the
machine is running at
half power.
controls the duration of
half power. 0 - 30 min.
illuminates when the
machine is running at
full power.
controls the duration of
full power setting.
7.
Maintenance
7.1 Filter replacement
1. Loosen the metal clips at the
cassette side plates.
2. Remove the used filter.
3. Insert the new filter so that the Trisk logo is
visible from the outside.
4. Push the long edges of the
filter into the cassette grooves.
5. Reattach the metal clips.
Attention!
The filter is a consumable and should not be
cleaned as this will result in the loss of its filtering
capacity.
7.2 IR lamp replacement
Attention!
Do not touch the aluminium-coated reflector or
the new IR lamp with your fingers. Remove the
protective paper on the IR lamp after you have
installed it.
1. Disconnect power supply.
2. Loosen the 2 top screws on
the front plate in accordance
with Section 5.8 of the
assembly instructions.
3. Disconnect the cable connector.
4. Loosen the 4 screws on the ends
of the reflector and remove the
reflector from the plate.
5. Remove the mesh and unscrew
the lamp from the end.
6. Install new lamps in reverse order.
CureMate 2
Metal clips
421062 rev 1