6.
Normal usage
Turn the main switch on. This will initiate the electronics.
Four dots will sequentially blink to indcate the start-up. Next
the top display will show 1P (1-phase). The lower display
shows the supply frequency 50 or 60 Hz.
When the start-up sequence is over, the displays shows the
active curing times in minutes. Flash-off at the upper and
full bake at the lower.
Use the + and - buttons below the displays to change the
settings. Pressing the buttons continously will rapidly in-
crease the setting. Each timer can be set between 0 and 30
min. The settings will remain even after power-off and serve
as default for the next curing operation.
Start the curing by pressing the On/Off button. The active
timer will flash and the heater will switch off automatically
when the set times have elapsed. The cassette fan will run
for another 3 minutes for cooling down.
After idling for 30 minutes, the unit enters stand-by mode
when a dot in each display flashes. Pressing any button will
activate the unit again.
NOTES:
- The FLASH OFF timer controls the duration of the half
power output of the emitters. The FULL BAKE timer controls
the duration of the full power output of the emitters. If both
FLASH OFF and FULL BAKE timers are used, the FLASH OFF
timer will count down first and upon switching off it will
engage the FULL BAKE timer automatically.
- To stop the unit before the time is out, press the On/Off
button.
- Altering timers is possible even during curing.
- If the temperature inside the control unit rises over 65 °C
(149 °F) , the unit switches off. The upper display will show
Ot and the lower the actual temperature. Automatic reset
when the temperature falls below 55 °C (131 °F) and the
unit is ready for operation again.
FLASH OFF TIMER
FLASH OFF SETTINGS
FULL BAKE TIMER
FULL BAKE SETTINGS
ON/OFF BUTTON
MAIN SwITcH
6
All manuals and user guides at all-guides.com
7.
7.1 Filter replacement
7.2 IR lamp replacement
Maintenance
1. Loosen the metal clips at the
cassette side plates.
2. Remove the used filter.
3. Insert the new filter so that the Trisk logo is
visible from the outside.
4. Push the long edges of the
filter into the cassette grooves.
5. Reattach the metal clips.
Metal clips
Attention!
The filter is a consumable and should not be cleaned as
this will result in the loss of its filtering capacity.
Attention!
Do not touch the aluminium reflector or the new IR
lamp with your fingers. Remove the protective paper on
the IR lamp after you have installed it.
1. Disconnect power supply.
2. Loosen the 2 top screws on
the front plate in accordance
with Section 1.8 of the
assembly instructions.
3. Disconnect the cable connector.
4. Loosen the 4 screws on the ends
of the reflector and remove the
reflector from the plate.
5. Remove the mesh and unscrew
the lamp from the end.
6. Install new lamps in reverse order.