Bathroom example (distances to be respected from a toilet)
1 Buffer zones.
2 Change direction because the cable is too close to the bathtub.
3 Gauges must always be perpendicular to the cable runs.
* Always validate the specifications of your sanitary unit; it is important to never install cable under the foot of
the toilet bowl. As a general rule, the cable must be installed at a minimum of 6 inches on each side from the
center of the toilet drain and at a minimum of 24 inches from the wall behind the toilet to the front of the toilet.
8
A Toilet seat
B Toilet base
C Toilet drain
Cable must
A
be installed
6''
at a minimum
distance of 6
B
C
inches on each
side from the
6''
center of the
toilet drain.
Minimum
distance of 24
inches from the
wall to the front
of the toilet.