STERWINS 1000 DW-4 Notice De Montage, Utilisation Et Entretien page 184

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 4
8.4 TROUBLESHOOTING
Problems
The pump is not
starting
The pump is not
draining
FR
Problems
ES
The pump is not
PT
stopping
IT
EL
The flow is not
suitable
PL
RU
The pump
KZ
stops for a brief
moment
UA
RO
8.5 FATAL CIRCUMSTANCES
EN
Power consumption too high
Performance reduced
Leakage of the motor housing
JHCT105.01.001
JHCT105.01.013
DANGER ! Risk of injury due to electric shock, fire and/or
serious injury. Warning ! Before any trouble shooting, switch
off the product and keep other person away.
Probable causes
- There is no electric current
- The floater switch is in
the low position (current
switched off )
- The floater mechanism is
blocked.
- The intake pipe is clogged
- The outlet pipe is clogged
- The turbine is blocked
- Presence of an air bubble
Probable causes
- The floater is blocked in
the high position
- The floater mechanism is
blocked.
- The draining pipe diameter
is not suitable
- The intake pipe is clogged
- The outlet pipe is clogged
- The turbine is blocked
- Use instructions have not
been followed
- The motor automatically
switches to safety position
- The pipe is not suitable
- The water is too hot. The
overheat protection device
is stopping the pump
Problems
Motor oil
White oil
Solutions
- Ensure that the electric
current is on.
- Raise the floater
- Shake the floater
- Check the water height
- Clean the intake pipe
- Clean the pipe
- Disassemble the base and
clean the turbine
- Tilt the pump to let out the
air bubble then put it back in
Solutions
vertical position
- Check there is no foreign
object which could block the
floater and put the floater back
in low position
17
- Shake the floater
- Replace the tube (40mm hose
is recommended)
- Clean the pipe or intake pipe
- Disassemble the base and
clean the turbine
- Check for the depth of
submersion.
- Replace the pipe following
use instructions
- Check that the water
temperature remains under
35°C.
Stop use and contact authorized service center
184
Сontact authorized service center
Stop use and contact authorized service center
0,012
2.5ML
Qualification
required
No qualification
required
No qualification
required
Qualification
required
No qualification
required
No qualification
required
No qualification
required
Action

Publicité

Table des Matières
loading

Table des Matières