On page 4 is the list of components. If the square is green, the state of the component is normal
regardless of whether it is in the left (closed) or right (open) column. If the square is red, the component
state is abnormal.
This screen gives the status in real time, meaning that when the stove is running, if a change occurs,
it will be visible immediately.
GREEN ICON
RED ICON

Electrical Components

When the stove is switched off and the components no longer function, it is possible to test each of
the following components:
• Ignitor
• Combusion blower
• Convection blower
Pages 5 and 6 are used to test all electrical components. By pressing the white square next to «Gear
Motor 1», the rotary valve motor will operate for 30 seconds. This will give you the opportunity to see
the valve turn and hear the motor running. The same principle works for all other components.
Pressing the white square
Operation Manual - 3000
Pressure switch is closed. This condition is normal if the
stove is in operation.
Pressure switch is open. This condition is normal if the
stove is OFF.
Pressure switch is closed. This condition is abnormal if
the stove is OFF.
Pressure switch is open. This condition is abnormal if
the stove is in operation.
• Exhaust blower
• Rotary valve motor (Gear Motor 1)
• Auger motor (Gear Motor 2)