WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY
DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. REFER TO THE OWNER'S INFORMATION MANUAL PROVIDED WITH THIS
APPLIANCE. INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
DO NOT OPERATE WITH GLASS DOOR REMOVED, CRACKED, OR BROKEN. THIS VENTED GAS FIREPLACE HEATER IS NOT FOR USE
WITH AIR FILTERS. REGISTER KIT MAY BE USED.
MISE EN GARDE : TOUT(E) INSTALLATION, RÉGLAGE, MODIFICATION, RÉPARATION OU ENTRETIEN NON APPROPRIÉ(E)
POURRONT CAUSER DES DOMMAGES MATÉRIELS, DES BLESSURES OU LA MORT. CONSULTEZ LE MANUEL DU PROPRIÉTAIRE
FOURNI AVEC CET APPAREIL. L'INSTALLATION ET L'ENTRETIEN DOIVENT ÊTRE FAITS PAR UN INSTALLATEUR QUALIFIÉ. N'UTILISEZ
PAS CE FOYER SI LA PORTE VITRÉE EST RETIRÉE, FISSURÉE OU CASSÉE. CE FOYER AU GAZ À ÉVACUATION DIRECTE NE DOIT
PAS ÊTRE UTILISÉ AVEC DES FILTRES À AIR. UN KIT DE REGISTRE PEUT ÊTRE UTILISÉ.
INPUT RATING / PUISSANCE D'ENTRÉE (BTU/H) 0-610m
MIN. INPUT RATING / PUISSANCE D'ENTRÉE MIN. (BTU/H) 0-610m
ORIFICE 0-610m
ORIFICE 610-1370m
INPUT RATING / PUISSANCE D'ENTRÉE (BTU/H) 610-1370m
MAXIMUM OUTPUT / PUISSANCE DE SORTIE MAXIMALE (BTU/H)
THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE AND MAY BE INSTALLED IN AN
AFTERMARKET, PERMANENTLY LOCATED MANUFACTURED (MOBILE) HOME WHERE NOT PROHIBITED BY LOCAL CODES. SEE
OWNER'S MANUAL FOR DETAILS. THIS APPLIANCE IS SUPPLIED WITH A CONVERSION KIT.
CET APPAREIL DOIT ÊTRE INSTALLÉ SEULEMENT AVEC LE TYPE DE GAZ INDIQUÉ SUR LA PLAQUE SIGNALÉTIQUE, ET PEUT ÊTRE
INSTALLÉ DANS UNE MAISON PRÉFABRIQUÉE (MOBILE) APRÈS LA VENTE INITIALE, SITUÉE EN PERMANENCE (MOBILE), LÀ OÙ LES
CODES LOCAUX NE L'INTERDISENT PAS. VOIR LES DÉTAILS DANS LE MANUEL DU PROPRIÉTAIRE. CET APPAREIL EST FOURNI AVEC
UN KIT DE CONVERSION.
MINIMUM CLEARANCES TO COMBUSTIBLE CONSTRUCTION / DÉGAGEMENTS MINIMUMS AUX MATÉRIAUX COMBUSTIBLES
UNIT TO SIDEWALL
(FOYER AU MUR LATÉRAL)
CAUTION: HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN, CLOTHING, FURNITURE, AND FLAMMABLE LIQUIDS OR
VAPORS AWAY.
ATTENTION : L'APPAREIL EST CHAUD LORSQU'IL FONCTIONNE. NE TOUCHEZ PAS L'APPAREIL. LES ENFANTS DOIVENT ÊTRE
SURVEILLÉS ET TENUS LOIN DE L'APPAREIL, DE MÊME QUE LES VÊTEMENTS, MEUBLES, LIQUIDES ET GAZ INFLAMMABLES.
ELECTRICAL RATING (ALIMENTATION ÉLECTRIQUE) : 120 VOLTS, 60 HERTZ, LESS THAN (COURANT INFÉRIEUR À) : 1,5 AMPÈRE.
NE JAMAIS ENLEVER NI DISSIMULER CETTE ÉTIQUETTE
MODÈLE: DXV35DT3
ÉTIQUETTE D'HOMOLOGATION DE SÉCURITÉ
LISTED DIRECT VENT GAS FIREPLACE HEATER
(FOYER AU GAZ HOMOLOGUÉ, À ÉVACUATION DIRECTE)
(NOT FOR USE WITH SOLID FUEL)
NE DOIT PAS ÊTRE UTILISÉ AVEC UN COMBUSTIBLE SOLIDE
MANUFACTURED BY (FABRIQUÉ PAR) : EVEN TEMP INC.
FOR (POUR) : JOHNSON GAS APPLIANCE CO. CEDAR RAPIDS, IOWA
CERTIFIED FOR CANADA (HOMOLOGUÉ POUR LE CANADA)
TESTED TO (TESTÉ SELON LES NORMES) :
ANSI Z21.88-2005 * CSA 2.33-2005
10 in. (254 mm)
10 po (254 mm)
DO NOT REMOVE OR COVER THIS LABEL
DXV35 DT3
NATURAL GAS
GAZ NATUREL
33 000
10 000
#49 Avant / #44 Arrière
#49 Avant / #45 Arrière
28 833
24 057
UNIT TOP TO 8" MANTEL
(DESSUS DU FOYER AU MANTEAU DE 8 po)
O
N
SÉRIE:
WH-DXV35 DT III- 0100###
55
LP GAS
GAZ PROPANE (GPL)*
*(GAZ DE PÉTROLE LIQUÉFIÉ)
33 000
13 000
3/64po Avant / 3/64po Arrière
3/64po Avant / #55 Arrière
28 061
23 974
14 in. (356 mm)
14 po (356 mm)
65-01-000401