Operation; Pre-Start Checklist; Start-Up; Shutdown - Senco PC1010 Mode D'emploi

Masquer les pouces Voir aussi pour PC1010:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 115

Pre-Start Checklist

1. Remove any moisture in the air compressor tank. Remove excessive pressure by pulling on the
safety relief valve ring or with an air tool, then open the air tank drain valve in the bottom of the air
tank. Close tightly when drained.
GB
2. Make sure the air compressor Motor Switch is in the
3. Make sure all safety valves are working correctly.
4. Make sure all guards and covers are in place and securely mounted.

Start-Up

1. Ensure the lever on the pressure switch box is in the
2. Plug the power cord into the grounded outlet.
3. Move the motor switch to the
4. This will allow the air compressor to
correct pressure is achieved. When pressure drops with usage, the air compressor will
up pressure again.
5. Set pressure by adjusting the pressure regulator knob counter-clockwise for less pressure and
clockwise for more pressure.
6. If you notice any unusual noise or vibration, stop the air compressor and refer to "Troubleshooting."

Shutdown

1. To stop the air compressor, move the lever on the motor switch to the
the air compressor by unplugging it from the power source. This could result in risk of electrocution.
2. Drain air from the air tank by releasing air with an attached air tool or by pulling on the safety relief
valve ring.
3. Once pressure in the air tanks register under 0.7 bar, open the drain valve under each air tank to
drain any moisture.
4. Allow the air compressor to cool down.
5. Wipe air compressor clean and store in a safe, non-freezing area.
Read the instruction manual before performing maintenance. The following procedures must be
performed when stopping the air compressor for maintenance or service.
1. Turn off the air compressor.
2. Disconnect cord from main power supply.
3. Open all drains.
4. Wait for the air compressor to cool before starting service.
12
Warning: Risk of bodily injury. NEVER attempt to open the drain valve when
more than 0.7 bar of air pressure is in the air tank!
ON (1)
position.
building up pressure in the air tanks and
Start

Maintenance

Warning: Never assume the air compressor is safe to work on just because it
is not operating. It could restart at any time!
Maintenance Chart
Procedure
Drain condensation in air tank(s)
Check for unusual noise/vibration
Check for air leaks
Inspect air filter
Clean exterior of compressor
Check safety relief valve

Operation

OFF (0)
position.
OFF (0)
position.
Daily Weekly Monthly
X
X
X
X
X
11
when
Stop
building
Start
OFF (0)
position. NEVER stop
X

Publicité

Table des Matières
loading

Table des Matières