FINNED CONDENSER CLEANING
Periodically check and remove from the finned
condenser unit (if present) the impurity (dust and
deposit) which remain among the fins of the condenser,
obstructing a good circulation of the air. A dirty condenser
reduces the performance of the equipment, increasing the
energy consumption.
Cleaning should be carried out with a soft brush or preferably
with a vacuum cleaner.
For a good preservation of the cabinet's body a periodical cleaning is necessary.
EXTERNAL BODY: When necessary, the external body should be cleaned with a cloth and a neutral
soap and water solution.
STAINLESS STEEL SURFACES: wash with warm water and mild detergent, rinse well and dry with
soft cloth. Avoid scouring pads etc. which will spoil the finish of the stainless steel.
SURFACES IN PLASTIC MATERIAL: wash with warm water and mild detergent, rinse well and
dry with soft cloth; under no circumstances should alcohol, methylated spirits or solvents be used.
GLASS SURFACES: only use products specifically designed for glass cleaning; it is not advisable to
use ordinary water which can leave a film of calcium on the surface of the glass.
For cleaning operation of the tank proceed as follows:
1) Remove the product from the tank.
2) Switch off the unit using main switch (see control panel) and unplug the unit.
3) Before cleaning the tank the inside temperature must be the same as the ambient.
4) Clean the tank; don't use too much water that could damage the motor fans; rinse and dry carefully.
5) Turn the unit on, with the night curtain (if present) lowered and 1 hour later you can load the product again.
Do not use jet of water to clean the cabinet: electrical wiring could be damaged.
Never use mechanical devices or any other means to accelerate the defrosting process,
other than those recommended by the manufacturer.
SEASONAL WORK
When the unit is kept unused for a long time, please take note of the following procedures:
- unplug the unit;
- clean and dry well the unit;
- cover the unit with a curtain, place it in a dry room and sheltered from the atmospheric agents.
-10-