7. Technical data
Connection method
Pluggable screw terminal block
Order No.
Pluggable spring-cage terminal block
Order No.
Logic input data
Nominal input voltage U
N
Permissible range
Typ. current consumption at U
N
Typ. switch-on and restart current
Maximum response time
Voltage dip bridging
Recovery time restart
Diagnostic and status indicator
Inputs (IN)
Number of safe inputs
Nominal voltage
Typ. current consumption at U
N
Signal level at "0"
Signal level at "1"
Switch-on delay
Diagnostic and status indicator
Output data
Safe semiconductor outputs
Ground switching outputs
Nominal voltage
Permissible range
Limiting continuous current
Max. capacitive load
Max. inductive load
Switch-off pulses
Short-circuit protection
Residual voltage at "0"
Diagnostic and status indicator
Clock outputs
Number
Nominal voltage
Limiting continuous current
Switch-off pulses
Short-circuit protection
Monitoring outputs
Number
Nominal voltage
Limiting continuous current
Short-circuit protection
General data
Permissible ambient temperature
Operation
Storage
Nominal operating mode
Degree of protection according to
Housing
VDE 0470 Part 1
Connection terminal blocks
Installation location
22
PSR-TRISAFE-S
PSR-SCP-24DC/TS/S
2986229
PSR-SPP-24DC/TS/S
2986232
24 V DC (A1/A2)
0.85 - 1.1 x U
N
200 mA
250 mA
< 30 ms
20 ms
< 5 ms
4 LEDs (green, red)
20 (up to SIL 3/IEC 62061)
24 V DC (to ground A2)
4 mA
< 5 V
> 11 V
< 35 ms
20 LEDs (green)
4 (Cat. 4/EN 13849-1/EN 954)
2
24 V DC (24 V/0 V)
0.85 - 1.1 x U
N
2 A (see derating)
1 μF
1 H
< 1 ms
Yes, to ground
< 1.2 V
4 LEDs (green)
2
24 V DC (A1/A2)
100 mA
< 1 ms
Yes
4
24 V DC (A1/A2)
100 mA
Yes
- 20 °C to 55°C
- 20 °C to 70°C
100% operating factor
IP20
IP20
Minimum IP54
General data
Electrical isolation
Surge protection
Air and creepage distances between the circuits
Rated voltage
Rated surge voltage
Pollution degree
Surge voltage category
Mounting position
Dimensions (W/H/D)
PSR-SCP-...
PSR-SPP-...
Conductor cross-section
Screw connection
Spring-cage connection
Housing material
Safety characteristic data
Category
as per EN 954-1
Performance level
as per ISO 13849-1
SILCL
as per IEC 62061
Safety Integrity Level (SIL)
as per IEC 61508
Parameters
as per ISO 13849
MTTF
[years]
D
Parameters
as per IEC 61508 (62061)
PFH
Proof test interval (T
)
[months]
1
1)
Specifications are applicable only if the safety function is requested at least once a year.
2)
Calculation basis: d
= 365.25 d; h
= 24 h; t
op
op
B10d (AC15 5 A) = 70,000; % of SIL = 15%.
3)
Since all diagnostics tests are carried out during operation, the service life for the proof test interval
is adopted.
Derating curve:
2
1,5
1
0,5
0
0
25 30 35 40 45 50 55 60
Yes, between power supply for logic
(A1/A2) and power supply for safe outputs
(24 V/0 V)
Suppressor diode
As per DIN EN 50178:1998-04 1
basic insulation
50 V
0.8 kV
2
III
Horizontal
(67.5/114.5/ 99) mm
(67.5/114.5/112) mm
2
0.2 - 2.5 mm
(AWG 24-12)
2
0.2 - 1.5 mm
(AWG 24-16)
Polyamide PA, non-reinforced
4
e
3
3
1) 2)
8324
1) 2)
-8
[1/h]
1.37 x 10
3)
20 years
= 3,600 s;
cycle
Ambient temperature [°C]
23