3 - TECHNICAL DATA
Nominal values:
Power supply voltage
Motor Voltage
Working frequency
Maximum current at frequency converter output
Maximum current at frequency converter input
Maximum motor rated power output
Range of apparent output power
Efficiency level
Protection rating
Protection degree
Type of action
Operation
Grounding systems distribution
*The auxiliary fan supplied for wall mounting has a protection rating of IP54
Limits of use:
- Minimum ambient temperature: -10ºC
- Maximum ambient temperature: +40ºC
- Variation in the supply voltage: +/- 10%
- Humidity range: 5% to 95% without condensation and vapour
- Maximum altitude: 2.000 meters
Eco-Design:
Stand-by
Loss
(W)
[e]motion TT3-11A
6,13
[e]motion TT3-30A
9,03
Power Supply Voltage
Supply Frequency
Maximum current IP
Motor Voltage
Rated Output Current
Maximum Current OP
Apparent Output Power
Recommended Motor Power
Units
[e]motion MT2-11A
V
220-240V Single phase
V
230V Three phase
Hz
A
A
kW
kVA
IT, TN-C, TN-S TT
25;25
25;50
25;100
90,50
92,96
91,62
88,59
93,73
93,68
Units
V
Hz
A
V
A
A
(kVA)
(kW)
[e]motion TT3-11A
400V Three phase
400V Three phase
50/60
50/60
11
11
20
12
2,2
4
3,3
5,4
--
96,73% (50Hz) - 97,61% (60 Hz)
IP 55*
IP 55*
2
2
2B
2B
S1
S1
IT, TN-C, TN-S TT
Load Point
50;25
50;50
50;100
Relative Loss [%] *1)2)3)
93,32
96,14
84,76
96,83
95,98
96,39
[e]motion TT3-11A
400
50/60
12
400 3Ph
11
11
7,6
4
29
EN
[e]motion TT3-30A
400V Three phase
400V Three phase
50/60
30
31
11
14,1
97,64% (50Hz) - 97,66% (60 Hz)
IP 55*
2
2B
S1
IT, TN-C, TN-S TT
IE
90;50
90;100
Class
97,61
96,73
IE2
97,66
97,64
IE2
[e]motion TT3-30A
400
50/60
31
400 3Ph
30
30
20,8
11