User Manual
Recovery of original EDID setting
Plug the power adapter into the transmitter and disconnect all other connectors. Push the self-EDID button
with a narrow pin. When the green EDID LED is totally turned off, the recovery procedure is
completed.
Installation
Do NOT introduce strain or stress to the fibre optic MPO cable and connectors!
Do NOT bend the fibre cable below the minimum allowed radius, approximately 10cm -
Important! Before starting the installation, please ensure that all devices are powered off.
1. Connect the power supply to both the transmitter (TX) and receiver (RX). Ensure the green power
LEDs near the DC connector are turned on (green)
Transmitter: If the graphics source can provide enough power to the TX via the DVI connector the
transmitter's power supply is not required. In this case make sure the green power LED is illuminated
brightly. A dim LED indicates insufficient power from the DVI port.
2. Connect the TX and RX to your DVI devices.
3. Remove the dust covers from TX and RX MPO ports and from your MPO Cable and connect it to TX
and RX. Make sure not to introduce dust or scratches to the surfaces!
4. Please make sure that the MPO connectors are fully engaged and then power on your display and
source to complete the installation.
5. If you can't get the proper resolution on the display, please go through the Self-EDID programming
procedure above and repeat the installation procedure again.
Troubleshooting Tips
If you cannot adjust the correct resolution of your monitor please follow the steps of Self-EDID learning
procedure.
If you cannot solve the problems contact your dealer or LINDY Tech Support. Find worldwide LINDY
contact information at www.lindy.com
see fiber cable supplier's specification!