To avoid scratches, spots and fingerprints, remove the PVC protective film with gloves without using sharp tools.
4.2. Placement
Select a location where the equipment can be installed away from possible sources of heat (like ovens or stoves) and away
from direct sunlight. Ensure good air circulation around the equipment, above all at the top, at least 50 cm of free space. Respect
the recommended distances and never obstruct the air vents grids: the lack of ventilation seriously affects the operation and can
lead to severe damage to the equipment.
4.3. Levelling
The equipment must be installed on a flat and sturdy surface, to ensure stability. The height adjustable telescopic legs should be adjusted for a
precise levelling.
4.4. Water drain
This equipment is fitted with a drain outlet for cleaning.
In case you do not opt for a connection to the sewer, use the condensed water tray placing it from the front on the sliders under the
equipment.
The drainage of condensed water can be compromised if the equipment is not leveled.
4.5. Electrical connection
The unit is supplied with a plug in accordance with current standards of practice and with a power cord whose length is sufficient to allow
connection to the mains.
The mains should be easily accessible and sized for the maximum consumption (see rating plate), and should have an EARTH
CABLE. Never use sockets or plugs without earth cable, nor use adapters or extension cords.
For direct connections to the network, you should always install an interrupting device (circuit breaker) in accordance with
international standards.
5
Usage
5.1. Indications
Our Y4 Slim blast chiller is a two-in-one cabinet, capable of delivering a rapid and uniform cooling (from 70ºC to 3ºC in 90 minutes), and ready
to operate as a holding refrigerator. Our Y5 Slim Blast Chiller & Freezer is capable of delivering a rapid and uniform cooling (from 70ºC to -18ºC in
240 minutes), and ready to operate as a refrigerator/freezer. To reduce energy consumption, optimize the equipment operation, and also improve
and extend the life of food, observe the following conditions:
Reduce the frequency and duration of doors and/or drawers openings;
Space food to allow good air circulation between them;
Do not exceed height limit indicated by the symbol
DO NOT EXCEED THE LIMITS OF MAXIMUM PERMISSIBLE LOAD (20 kg PER SHELF).
5.2. Defrost
Our equipment defrost is carried out automatically with electronic control, which can also be triggered manually. In any case, do not use sharp
objects (such as knives, screwdrivers, etc.) to remove a possible excess of ice. Defrost water goes down a tray located at the bottom of the
equipment or the cooling unit being automatically evaporated. In models that do not possess an automatic system of evaporation water, pour the
water tray regularly. After defrost, keep the door closed to accelerate the temperature recovery.
5.3. Cleaning
To ensure proper hygiene and maintenance, perform regular cleaning as indicated:
Switch off the appliance and unplug it, or switch off the circuit breaker;
Clean the surfaces using a dampened cloth with a mild detergent water solution; then rinse with a dampened cloth with clean water
and finally wipe with a dry cloth;
Do not use cleaning products containing acids or chlorine (such as bleach), or abrasive materials (such as pads) or pressurized water
(such as hoses).
5.4. Condenser Cleaning
To ensure long life and correct operation of the refrigeration system, clean the condenser regularly as indicated:
Switch off the appliance and unplug it, or switch off the circuit breaker;
Unscrew and open the air vents grid; be careful with cable holder, do not stretch the cables;
Carefully vacuum (preferably) or brush the condenser coils;
Finally, screw back the air vents grid.
5.5. Extended Period of Inactivity
Where there is a foreseeable extended period of inactivity, remove all foodstuff from the appliance and clean it as described. In the end, switch
it off from the mains and leave the door open to prevent bad odour.
5.6. Power cord replacement
IF DETERIORATED, THE POWER CORD MUST BE IMMEDIATELY REPLACED BY AN ORIGINAL ONE PROVIDED BY THE
MANUFACTURER OR BY AFTER-SALES SERVICE. THE REPLACEMENT MUST BE PERFORMED BY QUALIFIED PERSONNEL.
5.7. Noise emissions
Time-weighted of equipment noise emissions, in workplace, do not exceed 70 dB(A).
5.8. Troubleshooting
MNS00058.01
PRT
Instruction Manual
;
N.º MNS00058.01
4/20