FUSE CHECK/REPLACEMENT
For machine without battery charger only
1.
Disconnect the battery connector (29).
For machine with battery charger only
2.
Remove the recovery tank as shown in Use chapter.
For machine with battery charger only
3.
Disconnect the battery negative terminals (50).
4.
Remove the screws (A, Fig. 10), then carefully remove the electrical component box cover (B).
5.
Check/replace the following fuses:
•
Brush (40 A) (C)
•
Vacuum system (40 A) (D)
•
Solenoid valve and electronic board (5 A) (E)
6.
Install the components in the reverse order of removal.
909 6313 000(4)2009-11 A
A
B
A
Figure 9
USER MANUAL
E
D
C
SCRUBTEC 343B
ENGLISH
S311230B