ENGLISH
BATTERY TYPE SETTING (WET OR GEL)
Set the electronic board of the machine according to the type of
batteries installed (WET or GEL) as shown below:
Machine setting
1.
Check that the battery connector (29) is disconnected.
2.
The machine factory setting is for GEL batteries. If this
setting corresponds to the type of batteries installed, go to
step 6. Otherwise, perform steps 3, 4 and 5 too.
3.
Remove the screws (A, Fig. 1), then remove the electrical
component box cover (B).
4.
Turn the microswitch (C) to WET position.
WARNING!
Do not move/set the adjacent switch (D).
5.
Reinstall the electric component box cover (B) and tighten
the screws (A).
Battery installation
6.
Disconnect the vacuum hose (22) from the squeegee (11).
7.
Disconnect the recovery water drain hose (16) from the
bracket (17).
8.
Open the cover (6).
9.
Grasp the recovery tank (A, Fig. 2) in the area (B) and
slightly raise it.
10.
Disconnect the vacuum hose (C) from the tank, then
remove the tank (A) with the hoses (D) and (E).
11.
Install the batteries on the machine according to the
diagram (28).
12.
Install the tank (A, Fig. 2) by performing steps 6 to 10 in
the reverse order.
Battery charging
13.
Charge the batteries (see the procedure in Maintenance
chapter).
12
USER MANUAL
SCRUBTEC 343B
D
C
A
B
A
Figure 1
C
A
D
Figure 2
S311230A
B
E
S310233 A
909 6313 000(4)2009-11 A