Fail safe function – digital protection against radio interference. The safety electronic can detect reception of
a "false" or incomplete radio signal. E.g. due to a low transmitter battery or environmental radio interference which
reach the model, or if the model is out of the transmitter range. For protection against damage, servo
switches to the brake position and the model stops.
Setup:
1. Turn on the power of transmitter.
2. Connect power supply to receiver; LED on receiver should be solid.
3. Control the throttle trigger to make servo to "brake" or "stop" mode and remain for a while.
5. Setup is complete.
Testing:
1. Turn on the power of transmitter.
2. Connect power supply to receiver.
4. Servo which controlled by fail safe should go to brake modus automatically.
5. In case can be complete step by step with the above action, means setting is correct.
Failsafe Funktion – digitaler Schutz gegen Funkstörungen. Die Sicherheitselektronik erkennt, wenn „falsche"
zu Funkstörungen mit der Umgebung kommt oder wenn sich das Modell außerhalb der Reichweite des
Modell bleibt stehen.
Setup:
1. Den Sender einschalten.
3. Betätigen Sie den Gas Hebel in den Bremsmodus.
4. Die Setup-Taste auf dem Empfänger drücken. Die LED auf dem Empfänger blinkt und geht nach 3 Sekunden aus
5. Die Einrichtung ist abgeschlossen.
Test:
1. Den Sender einschalten.
2. Empfänger an die Stromversorgung anschließen.
3. Den Sender ausschalten.
4. Servo oder Drehzahlregler, die durch das Failsafe gesteuert werden, gehen automatisch in den eingestellten
Bremsmodus.
5. Wenn Vorstehendes vollständig durchgeführt werden kann, sind die Einstellungen korrekt.