WARNING
It is absolutely forbidden to connect the
unit to the public mains and/or another
electrical power source.
Areas for which access by non-authorized
personnel is forbidden are:
- the control panel (at the front) - the
endothermic motor discharge.
GENERATION IN C.C. (CONTINUOUS
CURRENT WITH MICRO-INTERRUPTION)
Machines with three pin outlets for auxiliary
supply have, at each outlet, isolated active and
neutral sockets, and an earth socket. Only the
earth socket is bonded to the frame of the
machine.
For your safety, all auxiliary equipment,
extension cords, appliance cords, plugs, plug
sockets and appliances should be in good
condition and correctly wired and connected.
All earthing wires, qhere used, must be
continuous. Extension corde with three wires
should be used except for double insulated
appliances.
The frame of the unit should not be
connected to the general mass of earth by
an earth spike or by any other means, but
should be isolated from earth.
Note: in line with current practice, a floating
auxiliary power system is used. The auxiliary
power windings are not connected to the fra-
me, hence a "residual current device" is not
required.
- If the generator is used to feed more complex
circuits, or used in special environments, for
example: building sites, it is obligatory to
interpose between the socket and the loads a
small distribution panel complete with electrical
safeties foreseen by regulatory norms in force
in matters of electrical installation.
Use as a generator
M
MAGIC WELD