5. How to Wire Your Industrial Fan
5.9
After Connections have been made, turn Wires and
Connectors upward and carefully push them into the
Outlet Box.
Slide the Receiver completely onto the Hanger Ball,
nestled in the Hanger Bracket (Figure 22).
WARNING
!
Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.
5.10
Wiring Schematic for reference (Figure 23).
NOTE: See Section 7 (page 16) for Wall Control
Installation.
BLACK
(HOT)
TO
120-VOLT
SUPPLY
WHITE
SUPPLY
GROUND
Figure 23
SUPPLIED
WALL CONTROL
GND
TWO-CONDUCTOR
CABLE
(WITH GROUND)
GREEN WIRE (GROUND)
FROM HANGER BRACKET
GREEN WIRE (GROUND)
FROM HANGER BALL
Figure 22
BLACK
BLACK
WHITE
WHITE
GREEN GROUND
GREEN GROUND
BLUE
BROWN
BLUE
GREY
HANGER BALL
HANGER BRACKET
14
(Continued)
WIRE
CONNECTORS
(Tucked Inside
Outlet Box)
GREY
BROWN
ETL Model No.: HF1161