OBO Bettermann UDHOME2 GE 2V 15 NO Instructions De Montage page 27

Boîtier de sol avec évidement du revêtement de sol et prise nf double
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

C onnect the double socket as shown . Also
connect the PE connection of the service
unit .
B end the separation panel downwards by
90° (1.), insert the double socket in the ser-
vice unit (2.) and screw it tight (3.) .
Applying the floor covering and adjusting
the height
Apply the floor covering, leaving an ex-
pansion joint of 1–5 mm to the service unit .
C ut out a key for the recess in the hinged lid
and, depending on the thickness of the floor
covering, stick it into the recess, flush to the
exterior frame of the hinged lid, using an ad-
ditional insert, e .g . with mounting adhesive .
a nd Adjust the height of the top edge of
the service unit, so that it is flush with the top
edge of the floor covering . To do so, unscrew
the four height adjustment supports accord-
ingly, using a slotted screwdriver .