Problem
No water outlet
Reduced flow rate
Wrong supply of mixed water
Water flows constantly
Wrong time flow rate (too short
or too long)
Obtain the correct inlet pressures and adjust them to 3 bar
To secure an anti-scalding on the mixers, install a safety thermostatic valve
The lever withstands a force of 30 Kg
Don't squeeze or bend the hoses
The time flow and the flow rate of non-regulated products, are depending on the pressure of the water
network
The taps must be installed by qualified technician
Mandatory installation of the filter seals – the installation of stop valves make the access to maintenance
easier
Troubleshooting
Cause
Stop valves are closed
Filters are clogged
Hoses are twisted or bent
Filters are clogged
Stop valves are not opened enough
Hoses are twisted or bent
Pressure is too low
Non-return valves are defective
Cartridge has been improperly configured
Cartouche is obstructed or dirty
Flow aerator obstructed
The pressions of hot and cold water are unbalanced
Non-return valves are defective
The temperature difference between cold and hot water
is too low
Hoses are twisted or bent
Stop valves are not opened enough
Cartridge is obstructed or dirty
Cartridge out of order
Wrong position of the limiter
Reduced flow rate
Important informations
Solution
Open the stop valves
Clean or replace
Connect correctly the hoses
Clean or replace
Open the stop valves
Connect correctly the hoses
Check the pipelines
Clean or remplace
Adjust the cartridge (see page ......)
Clean or replace
Clean or replace
Find the good pressure balance;
ΔP < 0.4bar
Clean or replace
Check the water inlets
Connect correctly the hoses
Open the stop valves
Clean or replace
Replace
Adjust the flow time limiter (see page......)
See « Reduced flow rate »