7. Installation
5.1. Mounting the camera
IMPORTANT!
The camera must be disconnected from the power supply during installation.
Use the accompanying drilling template for drilling
the mounting holes for the installation adapter. An
opening is provided on the installation adapter for
cabling at the side. A cable gland must be used
(M25x1.5) for cabling at the side. Use screw
anchors and screws that are appropriate to the
surface to fix the installation adapter in place.
Now remove the camera dome from the camera
module. Use the hexagon wrench provided to do
this.
To simplify installation, a retaining rope with
eye is provided in the installation adapter to allow
the camera module to be suspended.
Now guide the connecting cable through the
installation adapter and either into the ceiling or
through the side opening.
The connection to the installation cable can be
made inside the installation adapter if required.
Now insert the camera module into the installation adapter. When doing so, ensure that the guide rail
and guide notch of the installation adapter and camera module fit correctly. It is only then that the camera
module is in the correct position.
Now retighten the fixing screws of the camera module.
After orienting the camera module, attach the camera cap and camera dome.
Now fix the camera dome in place.
27