Lossnay Energy Recovery Ventilator
Models:
LGH-F300RX
-E, LGH-F470RX
5
Operating Instructions
Please read this manual carefully before use for proper and safe use.
Do not attempt to install the product by yourself.
Safety precautions
The following signs indicate that death or serious injury may be caused by failure to heed the precautions described below.
Do not turn the remote controller on or off when flammable
gas has leaked. (It could catch fire or cause explosion with
sparks released from electric contactor.)
Prohibited
Open windows to ventilate.
Do not modify or disassemble.
(It could cause fire, electric shock or injury.)
Do not
disassemble
Do not apply water to the unit and remote controller.
(Electrical shock can result.)
Do not wet
Do not poke your fingers or sticks into the air intake and
outlet while the product is operating.
(Failure to heed this warning may result in injury.)
Do not touch
Do not place a burning appliance in a place where it is
exposed directly to the wind from Lossnay. (It could cause an
accident as a result of incomplete combustion.)
Don't operate with the "BY-PASS" when heating the room in
winter. (Condensed water may drip from the unit and wet the
surface of ceiling.)
Do not use at a place where exposed to high temperatures
Prohibited
(104˚F (40˚C) or higher), naked flames, or in environment
with heavy fumes. (It could cause fire.)
Do not use in an environment such as a chemical factory,
where hazardous gases such as acidic gases, alkaline gases,
organic solvent fumes, paint fumes, or gases containing
corrosive components are generated. (It could malfunction.)
Names of the parts
Models LGH-F300, F470, F600 RX
Control box
Maintenance cover
Lossnay core
Air exhaust fan
-E, LGH-F600RX
5
WARNING
CAUTION
5
Lossnay core holder
Air supply fan
Damper plate
Air filter
1
-E, LGH-F1200RX
5
Don't operate with wet hands.
(Electrical shock can result.)
Wet hands prohibited
Use the specified power supply and voltage.
(Use of incorrect power supply could cause fire or electric shock.)
Make sure the power supply isolator is turned off on the
power distribution panel before starting maintenance.
(It could cause electric shock or injury if it is turned on.)
When any abnormal conditions (burning smell, or others)
The instructions
are observed, stop operation, turn off the power supply
given must be
isolator on the power distribution panel and consult your
followed.
dealer.
(Continuing operation under such conditions could cause,
electric shock, fire, or damage.)
Securely install parts after maintenance.
(It could cause injury if parts fall.)
Put on gloves during maintenance. (It could cause injury.)
Make sure the power supply isolator is turned off on the
power distribution panel when Lossnay is not used for a
long period of time. (It could cause electric shock, power
leakage, or fire as a result of deteriorated insulation.)
The instructions
The appliance is not be used by children or persons with
given must be
reduced physical, sensory or mental capabilities, or lack of
followed.
experience and knowledge, unless they have been given
supervision or instruction.
Children should be supervised to ensure that they do not
play with the appliance.
Model LGH-F1200 RX
Control box
Maintenance cover
Lossnay core
Air exhaust fan
1110875HC4801
-E
5
(For the user)
5
Lossnay core holder
Air supply fan
Air filter
Damper plate

Publicité

Table des Matières
loading

Sommaire des Matières pour Mitsubishi Electric Lossnay LGH-F300RX5-E

  • Page 1 1110875HC4801 Lossnay Energy Recovery Ventilator Models: LGH-F300RX -E, LGH-F470RX -E, LGH-F600RX -E, LGH-F1200RX Operating Instructions (For the user) Please read this manual carefully before use for proper and safe use. Do not attempt to install the product by yourself. Safety precautions The following signs indicate that death or serious injury may be caused by failure to heed the precautions described below.
  • Page 2 Operation Lossnay can be connected with Lossnay remote controllers (PZ-60DR-E, PZ-41SLB-E, PZ-52SF-E ), and other Systems (City malti, Mr.slim, Central controller (MELANS) ) Following shows the use of PZ-60DR-E, Please refer to the manuals for the other systems. For connection of a Lossnay remote controller (PZ-60DR-E) If the Lossnay’s operation is linked with the operation of an external device such as an air conditioner, the method of use will differ, so carry out the appropriate operation in accordance with the following table.
  • Page 3 Maintenance Remove all dust and dirt on air filters and Lossnay cores at regular Cleaning the parts intervals in order to prevent a deterioration in the Lossnay functions. Guideline: Clean the air filters once a year. 1) Air filters (or when [FILTER] and [CLEANING] are indicated on the remote Use a vacuum cleaner to remove light dust.
  • Page 4 Specifications Voltage (V) : 1-Phase 208 - 230 Noise Air volume Static pressure Exchange efficiency (%) Weight Line Power (dB(A)) Current Model name frequency consumption Enthalpy Below the (Hz) (CFM) (CMH) (InH2O) (Pa) Temperature (lbs) (kg) unit Heating Cooling LGH-F300RX 1.12 - 1.18 232 - 268 260 - 300 441 - 510 0.46 - 0.54 115 - 135...
  • Page 5 Ventilateur Lossnay à récupération d’énergie Modèles: LGH-F300RX -E. LGH-F470RX -E. LGH-F600RX -E. LGH-F1200RX Mode d’emploi (pour l’utilisateur) Veuillez lire attentivement ce manuel avant l’usage afin d’utiliser correctement cet appareil en toute sécurité. N’essayez pas de monter vous-même cet appareil. Consignes de sécurité Ces signes signalent les risques de mot ou de blessures graves auxquels on s'expose en ne prenant pas les précautions suivantes.
  • Page 6: Utilisation

    Utilisation Vous pouvez brancher Lossnay sur une télécommande Lossnay (PZ-60DR-E. PZ-41SLB-E. PZ-52SF-E) ou sur d’autres systèmes (télécommandes City multi ou Mr Slim (MELANS)). Nous vous illustrions l’utilisation de PZ-60DR-E. Veuillez consulter les manuels pour savoir comment utiliser les autres systèmes, Pour brancher une télécommande Lossnay (PZ-60DR-E) Etant donnée que le mode d’utilisation est différent si le fonctionnement de Lossnay dépend de celui d’un dispositif externe, tel qu’un climatiseur, consultez le tableau suivant pour savoir comment le faire fonctionner.
  • Page 7: Entretien

    Entretien Eliminez périodiquement la poussière et la saleté des filtres et des noyaux Nettoyage des pièces Lossnay afin d’éviter que les fonctions Lossnay ne se détériorent. Ligne directrice: Nettoyez les filtres une fois par an. 1) Filtres à air (ou lorsque “FILTER” et “CLEANING” s'affichent sur la télécommande) Enlevez le plus gros des poussières avec un aspirateur.
  • Page 8: Caractéristiques

    Caractéristiques Tension (V) : 1 - Monophasée 208 - 230 Bruit Volume d’air Pression statique Rendement de l’échange (%) Poids Fréquence Consommation (dB(A)) Nom du Intensité secteur électrique Enthalpie Sous modèle (Hz) (CFM) (CMH) (InH2O) (Pa) Température l’appareil (lbs) (kg) Chauffage Refroidissement LGH-F300RX 1,12 - 1,18...