INSTALLATION
Installing/Replacing the lamp
For the installation, you need one of the following lamps:
OMNILUX OMI 1200 100V/1200W
OSRAM HMI1200/GS 100V/1200W
PHILIPS MSI 1200W 100V/1200W
The lamp must only be changed when wearing appropriate protective clothing (protection glasses, protection
gloves, helmet with sight, leather apron).
The lamp life given by the manufacturer must never be exceeded. This is why you need to take notes on the
operational time of the lamp or check the operating hour meter (if available) regularly and replace the lamp in
time.
Keep exchanged lamp in a protective container and remove accordingly.
During the operation, the lamp reaches temperatures of up to 600° C.
Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 10 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
Procedure:
Step 1: Open the housing by loosening the fastening screws.
Step 2: If replacing the lamp, remove the old lamp from the lamp holder.
Step 3: Insert the lamp into the lamp holder.
Step 4: Replace the housing cover and tighten the fixation screws.
Mount the SL-1200 on the stand.
DANGER TO LIFE!
Only install the lamp with the device switched off!
Unplug from mains before!
No. 89302005
No. 89302010
No. 89302015
CAUTION!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
Do not operate this device with opened cover!
21/51