Dimensions in mm
X = fixing dimensions
Code Zone 2
2-pol. + PE 3-pol. + PE 3-pol. + N + PE
Wall socket 3-pole
Wall socket 4-pole and 5-pole
Plug 3-pole
Plug 4-pole
Plug 5-pole
Explosion protected plug and socket system
16A, GHG 516
1
Technical data
1.1
1.1
1.1
1.1
1.1
Plug and socket GHG 516
Plug and socket GHG 516
Plug and socket GHG 516
Plug and socket GHG 516
Plug and socket GHG 516
Marking acc. to 94/9/EC and directive:
EC type examination certificate:
Wall socket
3-pole
Plug
3-pole
Coupler
3-pole
Flange socket
3-pole
Wall socket
4-pole
Plug
4-pole
Coupler
4-pole
Flange socket
4-pole
Wall socket
5-pole
Plug
5-pole
Coupler
5-pole
Flange socket
5-pole
Rated voltage:
3-pole
4-pole
5-pole
Rated current:
Back-up fuse:
without thermal protection
with thermal protection
Switching capacity AC 3, 3-pole:
Switching capacity AC 3, 4-pole:
Switching capacity AC 3, 5-pole:
Perm. ambient temperature:
Special versions permit deviating temperatures.
Perm. storage temperature in original packing:
Protection category acc. to EN/IEC 60529
with closed and secured hinged cover as well
as combinations properly plugged together
Insulation class acc. to EN/IEC 61140:
Cable entry: (catalogue version)
Wall socket
Plug / Coupler
Supply terminal:
Wall socket, flange socket
Coupler
Plug
Test torques:
Cap nut of the entry
for min. cable Ø in Nm
for max. cable Ø in Nm
Cover screws
Terminals
Terminals plug
Self-cutting screws size 4
Self-cutting screws size 5
Weight: (catalogue version)
Wall socket
3-pole
Plug
3-pole
Coupler
3-pole
Flange socket
3-pole
Wall socket
4-pole
Plug
4-pole
Coupler
4-pole
Flange socket
4-pole
Wall socket
5-pole
Plug
5-pole
Coupler
5-pole
Flange socket
5-pole
Auxiliary contact, rated voltage:
Auxiliary contact, rated current:
II 3 G
GHG 516 43
PTB 99 ATEX 1115
GHG 516 73
PTB 99 ATEX 1115
GHG 516 33
PTB 99 ATEX 1115
GHG 516 83
PTB 99 ATEX 1115
GHG 516 44
PTB 99 ATEX 1115
GHG 516 74
PTB 99 ATEX 1115
GHG 516 34
PTB 99 ATEX 1115
GHG 516 84
PTB 99 ATEX 1115
GHG 516 45
PTB 99 ATEX 1115
GHG 516 75
PTB 99 ATEX 1115
GHG 516 35
PTB 99 ATEX 1115
GHG 516 85
PTB 99 ATEX 1115
up to 415 V, 50/60 Hz
up to 690 V, 50/60 Hz
up to 500 V, 50/60 Hz (690V with 5h)
max. 16 A
max. 25 A
max. 35 A gL
250 V/16 A
400 V/16 A
400 V/16 A
-20° C to +40° C (catalogue version)
-40° C to +80° C
IP 66 (catalogue version)
I - is complied with by the devices
1xM25 (Ø8 -17 mm) + 1x blanking plug M25
3-pole
4-pole
5-pole
Cross section
2 x 1.5 - 4 mm²
2 x 1.5 - 4 mm²
1 x 1.0 - 2.5 mm²
M20
3.50
2.50
2.5 Nm
2.5 Nm
1.5 Nm
1.6 Nm
3.0 Nm
GHG 516 43
approx.1.10 kg
GHG 516 73
approx.0.27 kg
GHG 516 33
approx.0.61 kg
GHG 516 83
approx.0.38 kg
GHG 516 44
approx.1.50 kg
GHG 516 74
approx.0.34 kg
GHG 516 34
approx.0.89 kg
GHG 516 84
approx.0.53 kg
GHG 516 45
approx.1.55 kg
GHG 516 75
approx.0.38 kg
GHG 516 35
approx.0.89 kg
GHG 516 85
approx.0.58 kg
250 VAC
AC / 5 A
COOPER Crouse-Hinds GmbH
Ex nC II C T6 / T5
Ø 8 - 19 mm
Ø 8 - 21 mm
Ø 12 - 21 mm
Stripped wire length
10 mm
10 mm
9 mm
M25
M32
5.00
8.00
3.50
5.00
DC / 0.03 A
7 7 7 7 7