GHG 516, 3-pole 50/60Hz
110-130V 220-250V
yellow
blue
GHG 516, 4-pole 50/60Hz
220-250V
380-415V
500V
blue
red
black
GHG 516, 5-pole 50/60Hz
220-250V
380-415V
500V
blue
red
black
Contact arrangement
GHG 516, 3-pole 50/60Hz
GHG 516, 4-pole 50/60Hz
w/o auxiliary contact with auxiliary contact
GHG 516, 5-pole 50/60Hz
w/o auxiliary contact with auxiliary contact
10
10
10
10
10
COOPER Crouse-Hinds GmbH
Explosion protected plug and socket system
16A, GHG 516
Care has to be taken that when fitting the
cable entries, sealing inserts appropriate to
the cable diameter are used.
In order to ensure the required minimum
protection category, the cable glands are to be
tightened down.
Overtightening might impair the protection
category.
All vacant metric COOPER CROUSE-HINDS /
CEAG cable entries shall be closed with the
certified blanking plug for metric cable
entries.
6.3.2
Plug/coupler
In general, only the sealing inserts fitted in the
690V
plug or in the coupler may be used. When
black
mounting the cable, attention has to be paid
that sealing inserts matching the cable
diameter be used. After having connected the
cable, the coupling ring (page 9, fig. 2, item 4)
is to be screwed fingertight until the sealing
effect is obtained. Then the screws item 5, of
the pull-relief item 6, are to be tightened
down.
Mind! Overtightening might impair the pull-
relief effect!
690V
black
6.4
Closing the device
In order to ensure the required minimum
protection category, the cover screws, the
screws of the plug and of the coupler shall be
tightened down.
The screws of the plug and the coupler shall
be tightened down.
Overtightening might impair the protection
category.
Any foreign matter shall be removed from
the device.
6.5
Taking into operation
Prior to taking the apparatus into operation,
the tests specified in the relevant national
regulations shall be carried out. Apart from
that, the correct functioning and installation of
the apparatus in accordance with these
operating instructions and other applicable
regulations will have to be checked.
Check the plug for any damages before
putting it in the socket.
The user must ensure that a uniform
equipotential earth applies throughout when
the plug and socket system is operated.
The inappropriate installation and operation
of the plugs and sockets can entail the loss
of warranty.
7
Maintenance/Servicing
The relevant national regulations which
apply to the maintenance/servicing of
electrical apparatus in explosive
atmospheres, shall be observed.
(IEC 60079-17).
Before opening the enclosure, make sure
that the device is disconnected from the
voltage, or take appropriate protective
measures.
The required maintenance intervals depend on
the specific application and will therefore have
to be determined by the user dependent on
the conditions of use.
When servicing the plugs and sockets, particularly
those parts that are decisive for their type of
protection against explosion will have to be
checked (e. g. intactness of flameproof enclosed
components, of the housing, firm fit of the cable
entries and efficacy of gaskets).
If during servicing, repairs prove to be necessary,
section 8 of these operating instructions will have
to be observed.
8
Repair/Overhaul/
Modifications
Repairs and overhaul may only be carried out
with genuine COOPER CROUSE-HINDS /
CEAG spare parts.
Should the flameproof enclosure be
damaged, only a replacement will be
permitted. In case of doubt, the respective
apparatus will have to be returned to
COOPER CROUSE-HINDS / CEAG for
repair.
Repairs that affect the explosion
protection, may only be carried out by
Cooper Crouse.Hinds or a qualified
electrician in compliance with the
applicable national rules (EN 60079-19).
Modifications to the device or changes of
its design are not permitted.
9
Disposal/Recycling
When the apparatus is disposed of, the
respective national regulations on waste
disposal will have to be observed. In order to
facilitate the recycling of individual
components, plastic parts are provided with
the identification mark of the plastic material
used.
Subject to modifications or supplement of the