Fault
The swivel arm cannot
be opened or closed
because the tool is
jammed in the bowl.
Fault
"5000 g" or "11.00 lb"
is flashing on the dis-
play.
"-990 g" or "-2.20 lb"
is flashing on the dis-
play.
"59:59 m:s" is flashing
on the display.
The display shows
"ERROR"
Cause and troubleshooting
Drive is not in the parked position after a safety sys-
tem has stopped processing or the power supply has
been interrupted.
Set the rotary switch to
1.
Eliminate the problem that caused the appliance to
2.
stop.
→ "Safety systems", Page 39
When the swivel arm is open, remove the tool and
3.
close the swivel arm.
Set the rotary switch briefly to and then back to
4.
⁠ .
a The drive remains on for a short time until the
parked position is reached.
Cause and troubleshooting
Display values of the scales have been exceeded.
Observe the display values of the scales.
→ "Display values of scales", Page 43
Display values of scales have not been attained.
Observe the display values of the scales.
→ "Display values of scales", Page 43
Display range of the timer has been exceeded.
Process food for not longer than 59 minutes and
59 seconds or reset the processing time within this
time.
→ "Reading off and resetting the processing time",
Page 44
Scales are exposed to excessive vibrations.
Do not use the appliance on worktops exposed to
vibrations, e.g. with a dishwasher running under-
neath.
Base is uneven.
Set up the appliance on a stable, level, clean and
1.
flat work surface.
Check whether all 4 feet are in contact with the
2.
work surface.
The feet are soiled.
Wipe the feet down with a damp cloth.
The scales have to be restarted.
To restart the scales:
1.
Press ⁠ .
Troubleshooting en
⁠ .