3. GENERAL OPERATION

3.1 Monitoring menu
In normal operating mode the BMV can display the values of selected
important parameters of your DC system. Use the + and - selection keys to
select the desired parameter.
Label
Description
V
Battery voltage: this readout is useful to make a rough
estimation of the battery's state-of-charge. A 12 V battery is
considered empty when it cannot maintain a voltage of 10.5 V
under load conditions. Excessive voltage drops for a charged
battery when under heavy load can also indicate that the
battery capacity is insufficient.
Starter battery voltage: this readout is useful to make a
VS*
rough estimation of the starter battery's state-of-charge.
I
Current: this represents the actual current flowing in to or out
of the battery. A discharge current is indicated as a negative
value (current flowing out of the battery). If for example a DC
to AC inverter draws 5 A from the battery, it will be displayed
as –5.0 A.
CE
Consumed Energy: this displays the amount of Ah consumed
from the battery. A fully charged battery sets this readout to
0.0 Ah (synchronized system). If a current of 12 A is drawn
from the battery for a period of 3hours, this readout will show –
36.0 Ah.
SOC
State-of-charge: this is the best way to monitor the actual
state of the battery. This readout represents the current
amount of energy left in the battery. A fully charged battery will
be indicated by a value of 100.0%. A fully discharged battery
will be indicated by a value of 0.0%.
Time-to-go: this is an estimation of how long the battery can
TTG
support the present load; until it needs recharging.
* BMV-602 Only
Units
V
V
A
Ah
%
h
17