4.4
UL-Ratings
Supply
24 VDC / max. 1 A, Class 2 (X30a)
Class 2 output
24 VDC / max. 700 mA
Maximum surrounding air
65 °C
temperature
Pollution degree
For use in an environment with
pollution degree 2.
X38
CAN interface (PIN 381, 382):
24 VDC / max. 20 mA, Class 2
Output (Pin 380):
24 VDC / max. 0,7 A
X39
RS-485 interface (PIN 391, 392):
24 VDC / max. 20 mA, Class 2
Output (Pin 390):
24 VDC / max. 0,7 A
X33
Input 21, 22;
each 24 VDC / max. 20 mA, Class 2
Digital Output;
24 VDC (Pin 333) / max. 200mA,
Class2
Output (Pin 330);
24 VDC / max. 0.7 A
X34
Input 23;
24 VDC / max. 20 mA, Class 2
Output (Pin 340);
24 VDC / max. 0.7 A
X36
Input 24, 25, 26;
24 VDC each / max. 20 mA, Class 2
Output (Pin 360);
24 VDC / max. 0.7 A
X37 / X37a
Foil key pad connection
X30a
Power Supply Input;
24 VDC / max. 1A
X40
CAN-Bus (internal connection to the
controller, non-isolated)
X400 / X400a
Connector for display; 5 VDC, 200 mA
1
Note: The maximum load of all Class 2 outputs shall not exceed 0.7 A
in any combination.
X35
2 inputs for external induction loop
(loop detector)
8 | 11
TST_RFUxK2-A_INSTALL_MUL_rev2.docx
X31 Relays Outputs
(OUT 5,
OUT 6,
OUT 7,
OUT 8)
X32 Relays Outputs
(OUT 9,
1
, Class 2
OUT 10)
2
The relay terminals X31 and X32 can be connected either to the mains
voltage, low voltage or class 2 circuits. Mixing different voltage circuits
within one terminal is not permitted.
1
, Class 2
The changeover contacts (OUT9/OUT10) on terminal X32 are also
intended for connection to the same voltage circuits. The connection of
different voltage circuits is not permitted For voltages above 150 V, it is
necessary that the "COMMON" terminals of OUT9 and OUT10 have the
same voltage potential.
1
, Class 2
NOTE
The interconnection of Class 2 outputs is prohibited.
1
, Class 2
Connection
X31
310-319
1
, Class 2
X32
320-325
X33
330-335
X34
340-342
1
, Class 2
X36
360-363
X35
350-353
X38
380-385
X39
390-393
In the field-wiring area, provisions for wiring for Class 2 and Class 3 circuits
shall meet the requirements for separation from Class 1 circuits in
accordance with Section 725 of the National Electrical Code, ANSI/NFPA
70 and Section 16 of the Canadian Electrical Code. Separation from power
and lighting circuits is required for Class 2 by one of the following means:
a) A permanent barrier shall be provided to separate the field installed
Class 2 conductors of secondary circuits from all other circuits or;
TST RFUxK2-A
Maximum load for each single output:
250 VAC, max. 3 A G.P.
30 VDC, 3 A G.P.
2
C300, R150 (Pilot Duty)
Maximum total load at all four outputs:
250 VAC, max. 3 A G.P.
30 VDC, 3 A G.P.
120 / 240 VAC, 180 VA (Pilot Duty)
125 / 250 VDC, 28 VA (Pilot Duty)
Maximum load for each single output:
2
250 VAC, max. 3 A G.P.
30 VDC, 3 A G.P.
C300, R150 (Pilot Duty)
Tightening
Cable size
torque
wiring
2
Lb-in
[NM]
AWG
(mm
)
(0,2 – 3,3)
24 - 12
3.5
(0,4)
Class 1
(0,2 – 3,3)
24 - 12
3.5
(0,4)
Class 2
(0,2 – 1,3)
24 - 16
2.2
(0,25)
Class 2
2019-04-04
b) Provisions need to be made to route the Class 1 or power circuit
conductors in order to maintain a minimum 1/4-in (6.35 mm) separation
from the conductors of the Class 2 circuits.
E-File No. E218753
4.5
Assembly and connection
DANGER
Risk of electric shock!
Before connecting the accessories, switch off the supply voltage of the
controller!
Do not switch on the supply voltage of the controller again until
the installation of the accessories has been completed, the
controller is covered and no live parts can be touched.
ATTENTION
First connect the terminals and then plug them onto the pin header of
the controller! This is the only way to ensure safe contact between the
terminal and the pin header.
NOTE
Use only 75 °C copper cable to connect to the expansion board.
NEC
The description of the connection to the controller can be found
in the assembly instructions of the respective controller.
Required tools: Cross screwdriver PH 1, slotted screwdriver size 0.6 x 3.5
and 0.4 x 2.5
4.6
Mounting for the TSTFUZ2 Series
See "Für TST FUZ2 Serie/For TST FUZ2 Series/Pour Série TST FUZ2",
figure on page 1.
TST FUZ2-B:
1. Attach the 3 spacers C to the real text display using the 3 screws B.
2. Connect the connection cable E to the connection X40.
3. Connect the connection cable G to the connection X30a.