4.2
Abbreviations and definitions
Abb./Fig.
Figure
Tab.
Table
Door and barrier controller with integrated frequency
Controller
converter or reversing contactor for triggering a
(TST)
motor.
The qualified specialists have been informed
concerning possible dangers in case of improper
behaviour by working with electrical equipment. The
Qualified
qualified specialists are familiar with the necessary
specialists
protective measures and devices. Furthermore, due
to their professional training and experience, the
qualified specialists have the necessary knowledge
for testing work equipment.
4.3
Product specification
The TST RFUxK2-A is an accessory of the company
FEIG ELECTRONIC GmbH and provides the following functions:
•
6 inputs, 6 relay outputs, 1 digital output, 2-channel multiplex induction
loop detectors, one 4-channel annual timer, one CAN interface and one
RS-485 interface.
•
All functions are adjustable by parameter via the controller.
4.3.1
Intended use
ATTENTION
TST RFUxK2-A and TST RFUxK2-E cannot be operated in parallel.
-The expansion board serves as input and output extension for serial
interfaces and detectors.
-The expansion board can be operated with the real text display TST
KKTA.
If the TST RFUxK2-A or TST RFUxK2-E is connected
to the CAN(0) interface inside the housing, the TST
RFUxK2-F can be operated in parallel.
Parallel operation of several TST RFUxK2 boards via
the other CAN interfaces is not possible!
Operation is only permitted with the following controllers:
CE
TST FUF2-A, -C, -F Series
TST FU3F-A, -C, -F Series
TST FU3F-AU, -CU, -FU Series
TST FUZ2-B, -C Series
TST FUZ2-CX -L, -P, -S Series
7 | 11
TST RFUxK2-A
TST_RFUxK2-A_INSTALL_MUL_rev2.docx
4.3.2
Technical data for Europe
Dimensions (LxWxH)
Temperature
Weight
Equipment type
Protection type
Protection class
Supply voltage
Power consumption
Current carrying capacity
Connection/interface
Other
X33 (IN 21), X34 (IN 23),
X36 (IN 24 – IN 26)
The 24 V outputs and transistor outputs are electronically fused
and may be loaded with max. 1.1 A (@23 °C) (resistive loads only)!
Relays OUT 5 – OUT 8
Relays OUT 9 – OUT 10
UL
Relay contact (general)
Digital Output
166 x 115 x 30 mm
Operation
-20 °C to +65 °C
Storage
-20 °C to +70 °C
approx. 290 g
Input and output expansion board
IP 00
--
24 VDC ± 20 %
max. 8 W
max. 0,7 A (@ Ta = 65 °C)
max. 1.1 A (@ Ta = 23 °C)
System interface (internal connection
to the controller),
1x CAN as external interface,
1x RS 485 as external interface
4-times seven-segment display (red),
optional 2x 16 characters plain text
display
Inputs
24 VDC / typ.15 mA,
max. 26 VDC / 20 mA
Outputs
Normally open contact with common
COM port.
Max. 230 VAC / 3 A in total are
allowed.
Changeover contact free of potential.
The same switching voltage shall be
used for both relays!
max. 230 VAC / 3 A, min. 10 mA. Once
relay contacts have been used for power
switching, they can no longer switch
very small currents!
OUT 11: 1 x 24 V / min. 10 mA / max.
100 mA, normally open, +24 V
switching!
2019-04-04
FEIG ELECTRONIC GmbH
Lange Straße 4 | D-35781 Weilburg
Tel. +49 6471 3109-0 | Mail:
Battery
Holder prepared for lithium coin cell
CR2032 (3V) Typical life: 5 years
Real-time clock:
Real-time clock: 24 hour clock with
calendar function, 4 channel evaluation,
Accuracy: less than 0.5 seconds per day
over the entire temperature range.
Induction Loop Detector
Channel multiplex Loop inductance
Loop 3, Loop 4
range:
25 – 1200 µH
(channel 3a, 3b, 4a, 4b)
Recommended loop inductance:
80 – 300 µH
Operating frequency: 30 – 140 kHz
Sensitivity: 0,005 % - 2,125 %
(Δf/f) in 256 steps
Max. Loop supply cable: 250 m
Max. Internal loop resistance:
20 Ω incl. supply line
Loop inputs: galvanic isolation 2 kV
(via spark gap)
Cycle time: 24 ms
Cable size
Connection
Stranded with
Solid
wire end ferrule
X31
310-319
0,2 - 2,5 mm²
0,25 - 1,5 mm²
X32
320-325
X33
330-335
X34
340-342
0,2 - 2,5 mm²
0,25 -1,5 mm²
X36
360-363
X35
350-353
X38
380-385
0,2 - 1,5 mm²
0,25 - 0,75 mm²
X39
390-393
EC installation declaration
Machinery Directive: 2006/42/EC
Low Voltage Directive: 2014/30/EU
Harmonised standards applied:
EN 60335-1:2012 / AC:2014
Section: Chapters 7, 10, 11, 13, 14, 16, 17, 19, 22, 23, 24, 29 and 30
EN 60335-2-103:2015
Section: Chapters 7, 10, 11, 13, 14, 16, 17, 19, 22, 23, 24, 29 and 30
EN 61000-6-1:2007 Section: Table 1 item 1.5, Table 2, Table 4 items 4.4
+ 4.5
EN 61000-6-2:2005 / AC:2005
Section: Table 1 item 1.5, Table 2, Table 4 items 4.4 + 4.5
info@feig.de
Tightening
torque
0,35 - 0,4 Nm
0,35 - 0,4 Nm
0,22 - 0,25 Nm
CONTROLLER