14. PARAMETERS SETTING

To programme the parameters of the boiler electronic board, proceed as follows:
• Press
and
together and hold them down for 6 seconds until programme row "P01" appears on the display alternated
with the set value;
• Press
to scroll the list of parameters;
• Press
the value of the selected begins flashing, press
• Press
to confirm the value or press
Further information concerning the parameters listed in the following table are supplied together with the required
accessories.
Remote
control*
Boiler
P01
P00
Manufacturer information
P02
P01
Gas used 00 = METHANE - 01 = LPG
Hydraulic system
00 = instantaneous appliance
P03
P02
03 = instantaneous appliance with pre-heating function
05 = appliance with external storage boiler
08 = heating only appliance
P04
P03
Programmable relay 1 settings
P05
P04
Programmable relay 2 settings
P06
P05
External probe input configuration (See SERVICE Instructions)
P07..P09
P06..P08
Manufacturer information
Heating setpoint setting OT / RT
(Remote Control - Open Therm / Room Thermostat 230V~)
00 = the temperature request is the Remote Control setpoint
P10
P09
01 = the temperature Request is the highest setpoint between Remote
Control and PCB
02 = the temperature request is the Remote Control setpoint.
The Room Thermostat enable the gas boiler operates
P11..P12
P10..P11
Manufacturer information
P13
P12
Max. heating output (0-100%)
P14
P13
Max DHW output
P15
P14
Min. heating output (0-100%)
P16
P15
Maximum CH setpoint (°C) 00 = 85°C - 01 = 45°C
P17
P16
Pump overrun time in heating mode (01-240 minutes)
P18
P17
Delay prior to new ignition in CH mode (00-10 minutes) - 00=10 seconds
P19
P18
Manufacturer information
P20
P19
Pump overrun time in DHW mode (seconds)
Anti-legionellosis function (°C) 00...54 = Disabled - 55...67 = Enabled
P21
P20
(set the desired temperature value)
P22
P21**
Manufacturer information
P23
P22
Maximum DHW setpoint temperature (ACS)
P24
P23
Manufacturer information
P25
P24
No water safety device
P26..P31
P25..P30
Manufacturer information
P32..P41
P31..P40
Diagnostics (See SERVICE Instructions)
Open Therm (OT) settings (See SERVICE Instructions)
P67
P66
02 = Open Therm Standard
* The modulating remote control must version 2.8 or higher
** Access to the installer settings using the modulating remote control is not possible
7679433.01 (1-04/17)
to exit without saving.
DESCRIPTION OF PARAMETERS
(See SERVICE instructions)
(See SERVICE instructions)
(0-100%)
14
to change the value;
FACTORY SETTINGS
24
08
100
20/24 MI 24/28 MI 28/33 MI
00
00
00
00
00
02
04
00
--
00
--
80
86
80
100
00
00
03
03
07
30
00
00
60
35
00
--
--
02