LEAK TESTING
GENERAL
Although gas connections on the grill are leak tested prior to shipment, a complete leak test must be
performed upon installation. Before each use, check all gas connections for leaks using the procedures
listed below.
If the smell of gas is detected at any time, you should immediately check the entire system for leaks.
BEFORE TESTING
Make sure all packing materials have been removed from the grill, including the burner tie-down straps.
WARNING
Check all gas supply fittings for leaks before each use. Do not use the grill until all connections have been
checked and do not leak. Do not smoke while leak testing. Never leak test with an open flame.
Make a solution of one part liquid detergent and one part water. You will need a spray bottle, brush, or
rag to apply the solution to the fittings. For the initial leak test, make sure the propane cylinder is 80% full.
TO TEST
1. Turn the burner valves off.
2. Turn the propane cylinder valve counterclockwise to open the valve.
3. Apply the soap solution to all gas fittings. Soap bubbles will appear where a leak is present.
4. If a leak is present, immediately turn the gas supply "OFF" and tighten leaky fittings.
5. Turn the gas back "ON" and recheck.
6. Should the gas continue to leak from any of the fittings, turn the gas supply "OFF" and contact
customer service at 1-866-206-0888
7. If there is evidence of excessive abrasion or wear, or the hose is cut, it must be replaced prior to the
outdoor cooking gas appliance being put into operation.
Only those parts recommended by the manufacturer should be used on the grill. Substitutions will void
the warranty.
WARNING
1. Storage of an outdoor cooking gas appliance indoor is permissible only if the cylinder is disconnected
and removed from the outdoor cooking gas appliance.
2. Cylinder must be stored outdoors out of the reach of children and must not be stored in a building,
garage or any other enclosed area.

INSTALLER FINAL CHECK

Maintain specified clearance of 24 inches from combustible materials and construction.
All internal packaging has been removed.
The hose and regulator are properly connected to the propane cylinder.
The unit has been tested and is free of leaks.
The gas supply shutoff valve has been located.
All burners are installed.
Keep the instruction manual for future reference.
WARNING
1. Do not store spare propane cylinders under or near this appliance.
2. Never fill the cylinder beyond 80 percent capacity.
3. If the information above is not followed exactly, a fire, possibly causing serious injury or death, may
occur.