Daily inspect the function and
existence of the safety appliances
before you start the machine.
Do not attempt operation in this case,
protect the machine by unplugging the
power cord.
Remove all loose clothing and confine
long hair.
Before operating the machine, remove
tie, rings, watches, other jewellery,
and roll up sleeves above the elbows.
Wear safety shoes; never wear leisure
shoes or sandals.
Always wear the approved working
outfit.
Do not wear gloves.
Wear goggles when working
Install the machine so that there is
sufficient space for safe operation and
work piece handling.
Keep work area well lighted.
The machine is designed to operate in
closed rooms and must be bolted to
the floor.
Make sure that the power cord does
not impede work and cause people to
trip.
Keep the floor around the machine
clean and free of scrap material, oil
and grease.
Stay alert!
Give your work undivided attention.
Use common sense. Do not operate
the machine when you are tired.
Do not operate the machine under the
influence of drugs, alcohol or any
medication. Be aware that medication
can change your behaviour.
Never reach into the machine while it
is operating or running down.
Never leave a running machine
unattended. Before you leave the
workplace switch off the machine.
Keep children and visitors a safe
distance from the work area.
Do not operate the electric tool near
inflamm able liquids or gases.
Observe the fire fighting and fire alert
options, for example the fire
extinguisher operation and place.
Do not use the machine in a dump
environment and do not expose it to
rain.
Work only with well sharpened tools.
Always close the chuck guard before
you start the machine.
Remove the chuck key and wrenches
before machine operation.
Specifications regarding the maximum
or minimum size of the work piece
must be observed.
Do not remove chips and work piece
parts until the machine is at a
standstill.
Do not stand on the machine.
Connection and repair work on the
electrical installation may be carried
out by a qualified electrician only.
Have a damaged or worn power cord
replaced immediately.
Never place your fingers in a position
where they could contact any rotating
tool, chuck or cutting chips.
Secure work piece against rotation.
Use fixtures, clamps or a vice to hold
the work piece.
Never hold the work piece with your
hands alone.
When using a vice, always fasten it to
the table.
Never do any works "freehand" (hand-
holding the work piece rather than
supporting it).
Never move the table while the
machine is running.
If a work piece overhangs the table
such that it will fall or tip if not held,
clamp it to the table or provide
auxiliary support.
Check the save clamping of the work
piece before starting the machine.
Remove cutting chips with the aid of
an appropriate chip hook when the
machine is at a standstill only.
Never stop the rotating chuck or tool
with your hands.
Measurements and adjustments may
be carried out when the machine is at
a standstill only.
Setup work may only be carried out
after the machine is protected against
accidental starting by pressing the
emergency stop button.
Maintenance and repair work may
only be carried out after the machine
is protected against accidental starting
by pulling the mains plug.
Do not use wire wheels or grinding
wheels on this machine.
4
3.3 Remaining hazards
When using the machine according to
regulations some remaining hazards
may still exist.
The rotating chuck, tool and cutting
chips can cause injury.
Thrown and hot work pieces and
cutting chips can lead to injury.
Chips, dust and noise can be health
hazards. Be sure to wear personal
protection gear such as safety
goggles, dust mask and ear
protection.
The use of incorrect mains supply or a
damaged power cord can lead to
injuries caused by electricity.
4. Machine specifications
4.1 Technical data
Drilling capacity
Tapping capacity
Spindle to column
Spindle nose to table
Spindle nose to base
Spindle taper
Spindle travel
Spindle speeds
variable, left/right
Belt in low
135-1000 / 270-2000rpm
Belt in high
270-2000 / 500-3800rpm
Column diameter
Table size
T-slots...2
Overall
840 x 610 x 1850mm
Net weight
Mains
400V ~3L/PE 50Hz
Output power
1,5 kW (2 HP) S1
Reference current
Extension cord (H07RN-F):
Installation fuse protection
4.2 Noise emission
Acoustic pressure level (EN 11202):
Idling
In operation
The specified values are emission
levels and are not necessarily to be
seen as safe operating levels.
As workplace conditions vary, this
information is intended to allow the
user to make a better estimation of the
hazards and risks involved only.
25mm
M16
280mm
max 830mm
1180mm
MT3
127mm
110mm
410 x 490mm
16mm
290 kg
3,3 A
4x1,5²
16A
71,7 dB (A)
84 dB (A)