Technical Specifications - Frico Portier PS210 1020 Mode D'emploi

Table des Matières

Publicité

Technical specifications

Type
Output
[kW]
PS210A
0
PS215A
0
Technical specifications
Type
Output
steps
[kW]
PS210E03 1,5/3
PS210E06 3/6
PS210E09 4,5/9
PS215E09 4,5/9
PS215E14 6,7/13,5 1200/1900
*
) Sound power (L
) measurements according to ISO 27327-2: 2014, Installation type E.
1
WA
*
) Sound pressure (L
). Conditions: Distance to the unit 5 metres. Directional factor: 2. Equivalent absorption area:
2
pA
200 m². At lowest/highest airflow.
) ∆t = temperature rise of passing air at maximum heat output and highest airflow.
*
3
*
) Alternative 400 V3~ + 230 V~ (operating supply) if the current is greater than 16 A. Applies when connecting
4
several units.
Protection class: IP21.
CE compliant.
Accessory
Control panel
Control panel
2-step Thermostat
Door contact
Ambient, no heat - Portier A
Airflow
Sound
power*
[m
/h]
[dB(A)]
3
1000/1300 70
1300/2000 72
Electrical heat - Portier E
∆t*
Airflow
Sound
3
power*
[m
/h]
[°C]
[dB(A)]
3
950/1200
10/8
66
950/1200
19/15
66
950/1200
28/23
66
1200/1900
23/14
66
34/21
66
Type
CB22
CB20
RTI2
MDC
Portier
1
Sound
Voltage
pressure*
1
2
[dB(A)]
[V]
44/54
230V~
46/56
230V~
3
Sound
Voltage
pressure*
1
2
[dB(A)]
[V]
44/50
230V~/400V3N~*
44/50
400V3N~*
44/50
400V3N~*
39/50
400V3N~*
39/50
400V3~ + 230V~
Amperage
Length
[A]
[mm]
0,45
1020
0,55
1530
Amp.
Length
[A]
[mm]
13,4/4,8 1020
4
9,2
1020
4
13,5
1020
4
13,5
1530
4
20,0
1530
Weight
[kg]
14
20
Weight
[kg]
17
17
17
24
24
9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Portier ps215 1530Portier ps210 816Portier ps215 1335

Table des Matières