CRS-WD-TA869
Technical
Specifications
Triggers
Magnet switch
Housing and
wall tamper
contact
(depending on
installation)
Zone input
Environmental conditions
Environment
EN50131-1
Relative
humidity
Operating
temperature
Storage
temperature
Housing
Color
Dimensions (H x W x D)
Magnet switch
Magnet
Bosch Security Systems
Opening
the contact.
Transmits an alarm
message if the top
of the housing is
removed from the
base or if the detec-
tor is torn off the
wall.
When externally
connected contacts
are triggered.
Indoors, dry
Environmental
class II
Up to 95%,
non-condensing
-10 °C to +55 °C
-20 °C to +80 °C
Cream white
13.5 x 3.5 x 2.5 cm
6.7 x 1.8 x 2.1 cm
Installation Manual
Installation Manual | en 17
Power supply requirements
Battery lifetime
Battery
requirements
Recommended
batteries
Supply voltage
Automatic
test signal
Message:
"Battery Low"
Connecting external contacts
Externally
connected
contacts
Wire size
Cable length for
external contact
F.01U.045.269 | V4 | 2014.12
Up to 5 years in
mode 1
Up to 3 years in
modes 2 & 3
Two 1.5 V alkaline
cells (AA)
- Duracell® MN1500
or PC1500
- Eveready® E91
- Panasonic®
AM-3PIX/B
2.3 VDC to 3.0 VDC
Every 24/31 hours at
least
On activation
or automatic test
signal. Following
a "Battery Low"
message, the bat-
tery should be
changed within four
weeks.
Normally closed
contact or normally
open contact
(potential free)
0.14 mm to 1.5 mm
Max. 3 m