MANUAL mode
To access MANUAL mode, press the 2 button; when the 3 light comes on the function is active. The 4-5 buttons are used
to select one of the five fan speeds, also active when the flue is cold.
The motor is started in automatic mode by a mechanical thermostat (the display shows WAIT), which is activated when
5
the temperature is at least 45°C (fixed value, not modifiable). The 6 led indicates that the thermostat contact is closed.
6
AUTOMATIC mode
To access AUTOMATIC mode, press the 2 button; when the 7 light comes on the function is active. Use the 5 button to
7
7
set the speed.
8
The 4-5 buttons are used to select one of the five fan speeds.
In automatic mode the COMFORT temperature can also be selected.
1 2 3 4
Press the 4 button to access the COMFORT temperature setting and then set the value using 4-5. This setting allows the
user to reduce fan noise when the room temperature measured by the probe inside the controller exceeds the comfort
set point; the motor operates one speed lower (this mode has no effect in first speed) and is signalled by the 8 led.
LANGUAGE menu.
Pressing and holding the 2 button accesses the LANGUAGE menu, where the display language can be changed using
the 4-5 buttons (IT, EN, DE, FR). Pressing the 2 button briefly again accesses the DISPLAY menu, where the brightness
can be adjusted (between 10 and 150). Pressing the 2 button briefly another time accesses the DEGREES menu, where
the temperature display can be set as °C or °F.
BUZZER menu
Pressing the 2 button briefly a final time accesses the buzzer menu, where audible buzzer can be enabled or disabled.
10
11
12
13
14

IMPORTANT:

The COMMAND must be connected to the mains with a differential line cut-off switch according to the regulations in force. Correct
operation of the command is assured only for the proper motor for which it has been manufactured. Improper use relieves the
manufacturer from each responsibility
3
Code 0020800 FAN ELECTRIC CONTROLLER
9
8
6
CONSOLE OPERATION.
This electronic controller for packaged units manages ventilation air flows.
OK
The controller is switched on or off by pressing and holding the 1 button.
5
1
During operation the display shows the set speed alternating with unit
status, led 9.
When the unit is off, the display also remains off.
The unit can be controlled MANUALLY or AUTOMATICALLY.
O1
REMOTE CONTROL OPERATION:
The electronic controller for packaged units can be managed by an IR remote control.
The controller is switched on or off by pressing and holding the 11-12 buttons.
To switch from MANUAL to AUTOMATIC on the IR remote control press the 13-14 buttons. The LED
corresponding to the operating mode comes on, manual 3 or automatic 7.
In MANUAL mode only the buttons in the 11-13 group are enabled for selecting one of the five speeds.
In AUTOMATIC mode, the buttons in the 12-14 group are enabled for selecting one of the five speeds, as well
as the buttons in the 11-13 group for changing the COMFORT set point.
The 10 LED comes on whenever a button is pressed on the remote control; if this does not happen, check
the batteries.
0020800_Regolatore_17-07-2014_Rev00